12 Technical data
62
FA ROTEX ESU - 07/2008
12
Technical data
Tab. 12-1 Basic data for the ROTEX E-SolarUnit
Basic data
Pos. in Fig. 12-1
Unit
Total storage capacity
litres
500
Empty weight
6
kg
110
Total filled weight
kg
610
Dimensions (L x B x H)
cm
79 x 79 x 181
Maximum permissible storage tank water temperature
°C
85
Average hourly temperature drop
K/h
0.1
Standby heating power
kWh/24h
1.8
Maximum operating pressure, heating/domestic water
7/9
bar
10/10
Material for all heat exchangers
Stainless steel 1.4404
Domestic hot water
Domestic water capacity
litres
24.5
Domestic water heat exchanger surface
m
2
5.5
Average specific thermal output
W/K
2470
Pressure drop in the domestic water heat
exchanger (at a withdrawal rate of 15 l/min)
mbar
185
Storage tank charging heat exchanger (stainless steel)
Water content heat exchanger
litres
10.4
Surface of charging heat exchanger
m
2
2.3
Average specific thermal output
W/K
1040
Pressure drop in heat exchanger 1
(at a flow rate of 1000 l/h)
mbar
96
Solar heating support
Heat exchanger surface area
m
2
0.43
Average specific thermal output
W/K
200
Pressure drop in heat exchanger
(at a flow rate of 1000 l/h)
mbar
18
Thermal output data
Pos. in Fig. 12-1
Unit
NL efficiency characteristic acc. to DIN 4708
1)
1.8
D value, spec. water flow acc. to EN 625
2)
10
l/min
22
Continuous output Q
D
according to DIN 4708
kW
9
Maximum draw-off rate for a duration of 10 min
(T
TK
= 10 °C/T
WW
=40 °C/T
SP
= 60 °C)
l/min
19
Hot water quantity without reheating with up to 15 l/min
draw-off rate (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 60 °C)
litres
220
Hot water volume with reheating at a draw-off rate of 15
l/min (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 60 °C)
litres
270
Temporary water volume in 10 min
3)
litres
190
Tab. 12-2 Thermal output data for the ROTEX E-SolarUnit
1)
Recharging with nominal output, flow temp. T
V
= 80 °C, initial storage tank temp. T
SP
= 65 °C, cold water temp. T
KW
= 10 °C, hot water temp. T
WW
= 45 °C
2)
The specif. water flow acc. to EN 625 is the domestic water flow, at an average temperature increase of 30 K, which the ROTEX ESU can supply if two draw-off
procedures each of 10 minutes duration are performed one after the other, assuming a charging temp. of 65 °C. A delay of 20 minutes between the two draw-off
procedures is usually assumed. The ROTEX ESU also achieves this value even if the delay is shorter.
3)
Recharging with nominal output, initial storage tank temp. T
SP
= 60 °C, cold water temp. T
KW
= 10 °C, hot water temp. T