39
SuperGuard and Piguard Plus
|
1.09
•
Water & Feed
:
o
Min/Max Water/Hour: A quantity of water per hour, below or above which the alarm is
activated.
o
Min/Max Feed/Hour: A quantity of feed per hour, below or above which the alarm is
activated.
•
Aux. Alarm
: When assigning a related function, alarm occurs if the associated digital input
fails to follow the relay. Digital input must be active when its associated relay is on.
If there is no related function the alarm turns on when digital input is active.
7.4 Alarm Reset
This screen resets the alarms.
ALARM RESET #01
Alarm Reset ►NO
To reset the alarm, press
Enter
and use the Round Arrows key to change from NO to YES.
7.5 Version
Use this window to check the controller's software version.
CONTROLLER
Piguard SuperGuard
Use the arrow keys to switch between controllers and press select to view the software version.
7.6 Read From Plug
There are two data plug types: regular and gold. The gold data plug can store up to eight different
settings. By naming each setting differently you can easily write/read data from the plug to the controller
and vice versa.
Read from Plug?
NO◄ YES
Use the arrow keys to shift from NO to YES and press
Enter to read from data plug.
Gold data plug
SELECT SETTING #1
1.
Room No.1
2.
Room No.2
3.
<NO SETTING>
…8.