Rossmax CalPro Instruction Manual Download Page 2

2

3

 

Table of Contents:

Introduction  ...................................................................................... 3
Preliminary Remarks ........................................................................... 3
Cautionary Notes ............................................................................... 3
Name/Function of Each Part ............................................................ 4,5
LCD Display Explanations ................................................................... 6
Using the AC Adapter ........................................................................ 7
Connect Methods ........................................................................... 7,8
Operation Procedures
  1. Data link status operation  ........................................................... 9
  2. Readout Mode  .......................................................................... 10
  3. Auto Calibration Mode  ............................................................. 18
  4. Measurement Count Display Mode  ........................................... 20
  5. Measurement Count Clearance Mode  ....................................... 21
  6. Calibration Reminder Setting Mode  .......................................... 22
  7. Pressure Gauge Mode  .......................................................... 23-25
Change "mmHg" to "kPa" ............................................................. 26
Error Messages ................................................................................ 27

Specifications

 ................................................................................... 28

Safety Certifications

 ......................................................................... 29

USA FCC Class B ............................................................................. 29
Maintenance of ROSSMAX Calibrator .............................................. 29

 

Introduction 

The calibration system developed by Rossmax Reasearch and Develop-
ment is equipped with the following features :

● 

Automatic device pressure checking

● 

Automatic device pressure calibration

● 

Measurement count check and reset

● 

Digital manometer

Which helps our partners to offer on-site and prompt calibration service 

to end users as well as significantly enhance customer satisfaction!

 

Preliminary Remarks

The quality of the device has been verified and conforms to the provi

-

sions of the Electromagnetic Compatibility EMC Directive 2014/30/EU; 
Low Voltage Directive (LVD) 2014/35/EU and EN/IEC 61010-1 :2010 Safe-
ty requirements for electrical equipment for measurement, control, and 
laboratory use - Part 1: General requirements.

 

Cautionary Notes

1.  The unit contains high-precision assemblies. Therefore, avoid extreme 

temperatures, humidity, and direct sunlight. Avoid dropping or strong-
ly shocking the main unit, and protect it from dust.

2.  The unit should not be operated by children so to avoid hazardous 

situations.

3.  If the unit is stored near freezing, allow it to acclimate at room tem-

perature before use.

4.  This unit is not field serviceable. You should not use any tool to open 

the device nor should you attempt to adjust anything inside the de-
vice. If you have any problems, please contact the store or the doctor 
from whom you purchased this unit or please contact Rossmax Inter-
national Ltd.

5.  Dispose of device, batteries, components and accessories according to 

local regulations.

6.  Data link can only be connected with Rossmax blood pressure monitor 

and calibrator. It cannot be used for any other purpose.

7.  Clean the device carefully with a slightly damp, soft cloth.

Summary of Contents for CalPro

Page 1: ...Instruction Manual Model CalPro Mobile Calibration System for Blood Pressure Monitor...

Page 2: ...and conforms to the provi sions of the Electromagnetic Compatibility EMC Directive 2014 30 EU Low Voltage Directive LVD 2014 35 EU and EN IEC 61010 1 2010 Safe ty requirements for electrical equipment...

Page 3: ...key ON OFF key Readout key Auto Calibration key Zero key Deflate key Inflate key Check Count key Clear Count key Set Count key Air tube socket Data Link Port AC Adapter Jack Data Link Cable Air Tube a...

Page 4: ...sing the device Connection Methods Upper Arm Blood Pressure Monitor 1 Connect the tube between the calibrator and the monitor to the air tube socket 2 Then connect the data link cable between the cali...

Page 5: ...ck count Clear count Set count Operation Procedures 1 Data link status operation Before operation make sure the air tube and the data link cable are securely connected to the calibrator and the blood...

Page 6: ...ssure points will be shown both the default pressure check point and the actual pressure measured will appear alternatively If FAIL appears press the Auto calibration key for re calibration After this...

Page 7: ...s complete press the Readout key for double check Checking the pressures between calibrator and monitor If the deviation of First Pressure Points is under 3mmHg the calibrator will automatically check...

Page 8: ...s complete press the Readout key for double check check point on Calibrator check point from Blood Pressure Monitor If deviation under 3mmHg If deviation over 3mmHg Automatic Check 4th Pressure Points...

Page 9: ...dout key for double check check point on Calibrator check point from Blood Pressure Monitor If deviation under 3mmHg If deviation over 3mmHg Readout Check is OK Calibrator Screen Blood Pressure Monito...

Page 10: ...successful PASS will appear Otherwise FAIL will appear If FAIL continues to appear return the monitor to the manufacturer for service mmHg Auto calibration mmHg Auto calibration mmHg Auto calibration...

Page 11: ...cessful PASS will appear and the number of uses appears Otherwise FAIL will appear 5 Measurement Count Clearance Mode Press Clear count to start RUN appears on LCD and the measurement cycles count num...

Page 12: ...essure checking of Rossmax digital manometer Before entering this mode set the monitor to Test Mode To set your monitor to Test Mode 7 1 Remove 1 battery If using adapter as a power source disconnect...

Page 13: ...key the pressure will decrease 1 mmHg accordingly i n fl a t e i n fl a t e d e fl a t e d e fl a t e i n fl a t e i n fl a t e d e fl a t e d e fl a t e i n fl a t e i n fl a t e d e fl a t e d e fl...

Page 14: ...re Monitor and perform the auto calibration mode again ERR Connection Error Turn off the Blood Pressure Monitor disconnect and reconnect the data link cable turn on the Blood Pressure Monitor and oper...

Page 15: ...14 F 140 F 10 90 RH max Points of Pressure Programming towards Blood Pressure Monitor 0 300 200 100 mmHg Points of Pressure Inspection towards Blood Pressure Monitor 0 30 60 90 120 150 180 210 240 27...

Page 16: ...oes not cover damage accidents or non compliance with the instruction manual Please contact your local seller dealer or www rossmax com Customer Name _____________________________________________ Addr...

Page 17: ...OBM_IB_CalPro_ EN_SW_ver1830 IN0CALPRO0000000XX Manufacturer Rossmax Swiss GmbH Tramstrasse 16 CH 9442 Berneck Switzerland www rossmax com...