background image

10. Limited Warranty

The full Rosslare Limited Warranty Statement is available in the Quick Links section on the Rosslare website at

www.rosslaresecurity.com

.

Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.

11. International Standards

Description

Latest Standard

Latest ER Directive

CE-EMC

EN 61000-6-3:2007/A1:2011/AC:2012

EN 50130-4:2011+A1:2014

EN IEC 61000-3-2:2019

EN 61000-3-3:2013 + A1:2019

AOC

EMC 2014/30/EU

CE-LVD

EN62368-1: 2014+A11:2017

RED 2014/53/EU

CE-RED

ETSI EN 300 328 V2.2.2 :2019

ETSI EN 300 330 V2.1.1: 2017

ETSI EN 301 489-1 V2.2.3 :2019

ETSI EN 301 489-3 V2.1.1:2019

ETSI EN 301 489-17 V3.2.4:2020

EN 50663:2017

EN 62479: 2010

EN 50364:2018

NB1

RED 2014/53/EU

FCC

FCC Part 15B

FCC Part 15C

FCC ID

www.rosslaresecurity.com

11

DISCLAIMER: The data contained within Rosslare’s materials or documentation is intended to provide only general information about products available for purchase from Rosslare Enterprises Ltd. and
its associated companies (“Rosslare”). Reasonable efforts have been made to ensure the accuracy of this information. However, it might contain typographic errors, inaccuracies, or omissions that may
relate to product descriptions, visual pictures, specifications, and other details. All technical specifications weights, measures and colors shown, are best approximations. Rosslare can not be held
responsible and assumes no legal liability for the accuracy or completeness of the information provided. Rosslare reserves the right to change, delete, or otherwise modify the information, which is
represented, at any time, without any prior notice.

© 2021 Rosslare Enterprises Ltd. All rights reserved.

For more information regarding support, visit

https://support.rosslaresecurity.com/portal/en/home

.

0

7

0

6

-0

9

6

0

7

4

5

+

0

0

Multi-Smart™ Readers Installation & User Guide

Summary of Contents for Multi-Smart AY-K35

Page 1: ...nologies are used by each reader The readers support SIA Open Supervised Device Protocol OSDP V2 including SCP mode Secured Channel Protocol allowing readers to connect to any controller that supports OSDP The readers also have a capacitive touch button on the surface which can be assigned functions such as Door Bell Exit Help Lights or other required outputs With simple installation the readers a...

Page 2: ...rating Humidity Range 0 to 95 non condensing Vandal Resistance IK09 Antimicrobial efficacy Inhibits bacteria proliferation by up to 99 8 Physical Characteristics Dimensions H x W x D 88 x 48 x 24 mm 3 46 x 1 89 x 0 94 in Weight 121 g 4 27 oz Read range is different for different smartphones and also is affected by a variety of factors Read range listed is statistical mean rounded to nearest centim...

Page 3: ...a 11 conductor 58 cm 22 8 in pigtail with exposed wires coated with solder The individual wires from the reader are color coded according the Wiegand standard When using a separate power supply for the reader this supply and that of the controller must have a common ground The reader s cable shield wire should be preferably attached to an earth ground or a signal ground connection at the panel or ...

Page 4: ...on the controller 5 Trim and insulate the ends of all unused conductors individually Do not short any unused wires together Wire Color Function Red Power Black Ground Green Data 0 Data White Data 1 Clock Orange Green LED Control Brown Red LED Control Purple Tamper Output Yellow Buzzer Control Blue RS 485 A OSDP Gray RS 485 B OSDP Pink Touch Button Black shrink Shield 4 Configuration 1 Download the...

Page 5: ...tion and configure the following Parameter Options Remarks Protocol Wiegand OSDP OSDP SC Clock and Data Wiegand 26 32 34 40 56 64 bit 26 bit default Toggle to select Reverse OSDP SC Install mode read write OSDP addresses 0 31 13 default Credentials reading standards 125 KHz EM ASK 125 KHz FSK ISO 14443A ISO 14443B ISO 15693 BLE Credential You can select multiple credentials All standards are selec...

Page 6: ... reading standards are automatically set to OFF If necessary select a standard again General purpose button Activation On Off If set to Off the following are hidden Set key as bell Keypad press duration Set key as bell 6 Bit Wiegand Rosslare format default 6 Bit Wiegand with Nibble Parity Bits 8 Bit Wiegand Nibble Complemented Single Key 4 Bit Wiegand Keypad press duration seconds 0 25 0 5 0 75 1 ...

Page 7: ...r each NFC supported Android smartphone The reader scans for NFC ID and transmits the ID number to the host controller via OSDP or Wiegand protocols 5 2 Rosslare BLE ID credentials Android and iOS The reader can read credentials from Rosslare BLE ID app or Mobile Credentials SDK via Bluetooth The reader scans for BLE ID and transmits the ID number to the host controller via OSDP or Wiegand protoco...

Page 8: ...ader from its mounted location to expose the tamper to light 3 Connect the orange wire green LED control and yellow wire Buzzer Control to GND When the reset is complete the LED will blink in the sequence green yellow green yellow for two seconds while the buzzer will operate 4 Turn on the power to the reader and keep the orange wire and yellow wire to GND for four or more seconds When the restore...

Page 9: ...er on the Wiegand port Then the reader will return to standby mode and the right light bar stays solid RED 7 Touch Button Operation The General Purpose Button is located in the center of the reader Connect the pink wire to an available input of the controller The general purpose button is used to operate a bell or do other functions The general purpose has a LED The LED comes on when the general p...

Page 10: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interf...

Page 11: ...he data contained within Rosslare s materials or documentation is intended to provide only general information about products available for purchase from Rosslare Enterprises Ltd and its associated companies Rosslare Reasonable efforts have been made to ensure the accuracy of this information However it might contain typographic errors inaccuracies or omissions that may relate to product descripti...

Reviews: