Reader Functionality
AYC-x6355 (Rev. B) Installation and User Manual
21
6.
Reader Functionality
Upon power on, the unit flashes red, then green, and then orange,
each for 1 second and a beep is heard for each color. The unit
searches for the presence of Rosslare's secured intelligent power
supply. If a secured intelligent power supply is not detected, the unit
is automatically configured as a reader.
6.1
Standby Mode
The default mode of the reader is Standby mode. In Standby mode,
the unit is ready to receive data from a presented proximity card or an
entered PIN code.
When the reader is in Standby mode, the left LED
is red and the right LED is off.
When a proximity card is presented or a keypad
entry is being transmitted, the left LED flashes
green.
Keypad data can be sent via one of eight different Keypad
Transmission Formats (see Section
Proximity cards presented to the reader are sent in either various
Wiegand formats or Clock & Data format (see Section
6.2
Programming as a Reader
Programming is done solely via the unit's keypad driven Programming
Menu System. During the manufacturing process, certain codes and
settings are pre-programmed. These settings are called the default
factory settings.
Table 3 shows the names of all the reader menus.
Default factory settings are marked by a "*" sign.
Red
Green