Controller Functionality
AYC-Qx4 family manual
Page 45
Auxiliary Mode 2
Auxiliary input function:
Toggles normal/secure modes
Auxiliary output activated by: Asterisk Button (
*
)
E.g. In auxiliary mode 2, the auxiliary relay can function as a
general purpose time switch that can be activated when the
Asterisk button (*) is depressed. The auxiliary setting establishes for
how long the auxiliary relay is to be activated. The auxiliary input
can switch the mode of operation of the controller between
normal and secure mode. By connecting a switch timer or alarm
system output to the auxiliary input, the controller can be
automatically switched from normal mode (during office hours) to
secure mode (after office hours).
Auxiliary Mode 3
Auxiliary input function:
Toggles normal/secure modes
Auxiliary output activated by: Alarms
E.g. In auxiliary mode 3, the auxiliary output is activated if the
controller is tampered; that is, if the case is forcibly opened or
removed from the wall. The auxiliary input can switch the mode of
operation of the controller between normal and secure mode. By
connecting a switch timer or alarm system output to the auxiliary
input, the controller can be automatically switched from normal
mode (during office hours) to secure mode (after office hours).