![Rosslare AYC-Q Series Instruction Manual Download Page 29](http://html1.mh-extra.com/html/rosslare/ayc-q-series/ayc-q-series_instruction-manual_1489267029.webp)
Controller Functionality
AYC-Qx4 family manual
Page 28
6.
Controller Functionality
The AYC-Qx4 series can function both as a reader and as a
controller. If the unit is connected to Rosslares’ secure application
appurtenance, it functions as a controller indicated by two beeps
immediately after power-on reset.
The lock strike output and Request to Exit input are not located on
the AYC-Qx4 unit, eliminating the possibility of unauthorized entry
to the restricted area.
The following explains how the AYC-Qx4 series functions as a
controller.
6.1
Normal, Secure, and Master Users
The AYC-Qx4 accepts up to 500 users and provides entry via the
use of PIN codes and/or Proximity cards. Each user is provided
with two code memory slots, Memory Slot 1 (Primary Code) and
Memory Slot 2 (Secondary Code).
The pin code length has several options. The pin code length can
be a set number of 4, 5 or 6 digits or it can be a 4-8 digits option.
When choosing the 4-8 digit option, please note that you should
either enter zeros before the code, or press pound at the end (for
example if your code is 12345, enter either 00012345 or 12345#).
Note:
•
Entering a code refers to either PIN or CARD depending on
the model you have.