![Rosslare AY-Q64 Installation And Programming Manual Download Page 8](http://html.mh-extra.com/html/rosslare/ay-q64/ay-q64_installation-and-programming-manual_1489285008.webp)
Technical Specifications
8
AY-Q64 Installation and Programming Manual
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Linear type – recommended
Operating Voltage Range
5–16 VDC
Input Current
(not including attached
devices)
Standby: 30 mA
Max: 98 mA
Card Read Distance*
2.5 in. (65 mm) maximum read range
Proximity Card Modulation
•
26-Bit Wiegand, ASK at 125 KHz
•
Clock & Data, ASK at 125 KHz
Proximity Card Compatibility
All 26-Bit EM cards
Keypad Transmit Format
•
Single Key, Wiegand 6-Bit (Rosslare
Format)
•
Single Key, Wiegand 6-Bit with Nibble
and Parity Bits
•
Single Key, Wiegand 8-Bit, Nibbles
Complemented
•
4 Keys Facility Code, Wiegand
26-Bit
•
1 to 5 Keys + Facility Code, Wiegand
26-Bit
•
6 Keys BCD and Parity Bits, Wiegand
26-Bit
•
Single Key, 3x4 Matrix Keypad
•
1 to 8 Keys BCD, Clock & Data
LED Control Input
Dry Contact, N.O.
Tamper Output
Open Collector, active low, maximum sink
current is 32 mA
* Measured using Rosslare Proximity Card (AT-14) or equivalent. Range also
depends on electrical environment and proximity to metal