background image

2)

"0"

Menu 0

3)

Press

to enter

The Transmit LED will flash red
The Program LED will flash red

Enter your 4-digit Programming
Code.

If the Programming Code is valid, all memory will be erased,

you will hear three beeps and the controller will return to
Normal Mode

If the Programming Code is invalid you will hear a long beep

and the controller will return to Normal Mode without erasing
the memory of the controller.

In the event that the Programming Code is forgotten, the AY-Q54
may be reprogrammed in the field using the following instructions:

!

!

!

!

Replacing a lost Programming Code

1)

2)

3)

4)

Remove power from the reader.

Activate tamper by removing the reader from the wall or removing

the reader’s case.

Apply power to the reader.

You now have 10 seconds to enter Programming Mode using the

factory default Programming Code 1234.

Page 20

06/01

AY-Q54

? ? ? ?

Page 21

08/01

Technical Support

http:///www.rosslare.com.hk/support/

Rosslare Enterprises Ltd.
905-912 Wing Fat Industrial Bldg.,
12 Wang Tai Road, Kowloon Bay,
Hong Kong.

Tel:

(852) 2795 5630

Fax:

(852) 2795 1508

E-mail:

[email protected]

Rosslare Security Products S.r.l
Via F.lli Gabba 5, 20121 Milano, Italy

Tel:

(39) 0382 24800

Fax:

(39) 0382 24800

E-mail:

[email protected]
[email protected]

Rosslare NAPDC
Suite 238, 200 East Howard Street,
Des Plaines, IL 60018
USA

Tel:

(847) 827 6330

Fax:

(847) 827 5433

E-mail:

[email protected]

International Web Site:

Asia, Australia, & South America

Europe, Russia, Middle East, Africa

United States and Canada

:

:

:

AY-Q54

Summary of Contents for AY-Q54

Page 1: ...ROSSLARE INSTRUCTION MANUAL AY Q54 KEYPAD READER WIEGAND AND CLOCK DATA 08 01 9J IDR 024 A 0706 0820024 01 ROSSLAR E www rosslare com hk ROSSLAR E 1 2 3 4 5 6 7 8 9 0...

Page 2: ...er Supply Other Rosslare accessories can be found at Rosslare s Web Site http www rosslare com hk Additional Equipment Required 1 Compatible Host Controller 2 Power Supply AY Q54 Page 2 06 01 Contents...

Page 3: ...Technical Specification Electrical Characteristics Environmental Characteristics Operating Voltage Range Maximum Input Current Built In Keypad Reader LED Control Input Tamper Output Operating Temperat...

Page 4: ...ng the supplied security screw in the controllers Installation Kit An L Shaped tool is provided for use when tightening the security screw AY Q54 A A B B B B CAUTION DO NOT DRILL This is the Tamper Le...

Page 5: ...26 Bit Wiegand 5 1 to 5 Keys Facility Code 26 Bit Wiegand 6 6 Keys BCD and Parity Bits 26 Bit Wiegand 7 Single Key 3x4 Matrix Keypad 8 1 to 8 Keys BCD Clock Data Single Key Programming Menu Selecting...

Page 6: ...uired to specify the number of keys in the PIN code 1 2 1 Menu 1 3 4 Note Page 11 06 01 AY Q54 Transmit Program GREEN Page 10 06 01 Entering Programming Mode Exiting Programming Mode 1 2 Note 1 2 3 Pr...

Page 7: ...4 bits with 2 parity bits added Even parity for the first 3 bits and odd parity for the last 3 bits 0 0 0000 1 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1...

Page 8: ...ode the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card 1 to 5 Keys Facility Code 26 Bit Wiegand If the key or the key are pressed during PIN code entry o...

Page 9: ...2 2 0x32 hex 8 8 0x38 hex 3 3 0x33 hex 9 9 0x39 hex 4 4 0x34 hex 0x2A hex 5 5 0x35 hex 0x23 hex Buffers up to 8 keys and outputs keypad data without a facility code like standard Clock and Data card o...

Page 10: ...ng Mode Press to enter The Transmit LED will flash orange Enter the new 3 digit code you wish to set as Facility Code System returns to Transmit Mode You will hear one beep The Program LED will turn o...

Page 11: ...ing the reader from the wall or removing the reader s case Apply power to the reader You now have 10 seconds to enter Programming Mode using the factory default Programming Code 1234 Page 20 06 01 AY...