background image

Keypad Transmission Format Option Number

Single Key, 6-Bit Wiegand (Rosslare Format)

See the table below to determine the Option Number for the Keypad
Transmission Format you wish to select.

Single Key, 6-Bit Wiegand (Rosslare Format)

1

Single Key, 6-Bit Wiegand with  Parity Bits

2

Single Key, 8-Bit Wiegand, Nibbles Complemented

3

4 Keys  Facility Code, 26-Bit Wiegand

4

1 to 5 Keys + Facility Code, 26-Bit Wiegand

5

6 Keys BCD and Parity Bits, 26-Bit Wiegand

6

Single Key, 3x4 Matrix Keypad

7

1 to 8 Keys BCD, Clock & Data Single Key,

8

More information on each of the different keypad transmission
formats is available below and on the following pages.

Each key press immediately sends 4 bits with 2 parity bits added.
Even parity for the first 3 bits and odd parity for the last 3 bits.

0 = 1 1010 0

6 = 1 0110 0

1 = 0 0001 0

7 = 1 0111 1

2 = 0 0010 0

8 = 1 1000 1

3 = 0 0011 1

9 = 1 1001 0

4 = 1 0100 1

= 1 1011 1 = “B” in Hexadecimal

5 = 1 0101 0

# = 0 1101 1 = “C” in Hexadecimal

Each key press immediately sends 4 bits with 2 parity bits added.
Even parity for the first 3 bits and odd parity for the last 3 bits.

0 = 0 0000 1

6 = 1 0110 0

1 = 0 0001 0

7 = 1 0111 1

2 = 0 0010 0

8 = 1 1000 1

3 = 0 0011 1

9 = 1 1001 0

4 = 1 0100 1

= 1 1010 0 = “B” in Hexadecimal

5 = 1 0101 0

# = 1 1011 1 = “C” in Hexadecimal

Inverts the most significant bits in the message leaving the least 4
significant bits as Binary-Coded Decimal (BCD) representation of
the key. The host system receives an 8-bit message.

0 = 11110000

6 = 10010110

1 = 11100001

7 = 10000111

2 = 11010010

8 = 01111000

3 = 11000011

9 = 01101001

4 = 10110100

= 01011010 = “A” in Hexadecimal

5 = 10100101

# = 01001011 = “B” in Hexadecimal

Buffers 4 keys and outputs keypad data with a three digit facility
code like a standard 26-Bit card output.

The facility code is set in Programming Menu number four and can
be in the range 000 to 254. The factory default setting for the facility
code is 000. (See page 21 for more information on “Changing the
Facility Code”)

Single Key, 6-Bit Wiegand, Nibble & Parities

Single Key, 8-Bit Wiegand, Nibbles Complemented

4 Keys  Facility Code, 26-Bit Wiegand

Page 13

06/01

AY-Q54

Page 12

06/01

AY-Q54

Keypad Transmission Format

Option

Number

OPTION 1

OPTION 2

OPTION 3

OPTION 4

Summary of Contents for AY-Q54

Page 1: ...ROSSLARE INSTRUCTION MANUAL AY Q54 KEYPAD READER WIEGAND AND CLOCK DATA 08 01 9J IDR 024 A 0706 0820024 01 ROSSLAR E www rosslare com hk ROSSLAR E 1 2 3 4 5 6 7 8 9 0...

Page 2: ...er Supply Other Rosslare accessories can be found at Rosslare s Web Site http www rosslare com hk Additional Equipment Required 1 Compatible Host Controller 2 Power Supply AY Q54 Page 2 06 01 Contents...

Page 3: ...Technical Specification Electrical Characteristics Environmental Characteristics Operating Voltage Range Maximum Input Current Built In Keypad Reader LED Control Input Tamper Output Operating Temperat...

Page 4: ...ng the supplied security screw in the controllers Installation Kit An L Shaped tool is provided for use when tightening the security screw AY Q54 A A B B B B CAUTION DO NOT DRILL This is the Tamper Le...

Page 5: ...26 Bit Wiegand 5 1 to 5 Keys Facility Code 26 Bit Wiegand 6 6 Keys BCD and Parity Bits 26 Bit Wiegand 7 Single Key 3x4 Matrix Keypad 8 1 to 8 Keys BCD Clock Data Single Key Programming Menu Selecting...

Page 6: ...uired to specify the number of keys in the PIN code 1 2 1 Menu 1 3 4 Note Page 11 06 01 AY Q54 Transmit Program GREEN Page 10 06 01 Entering Programming Mode Exiting Programming Mode 1 2 Note 1 2 3 Pr...

Page 7: ...4 bits with 2 parity bits added Even parity for the first 3 bits and odd parity for the last 3 bits 0 0 0000 1 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1...

Page 8: ...ode the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card 1 to 5 Keys Facility Code 26 Bit Wiegand If the key or the key are pressed during PIN code entry o...

Page 9: ...2 2 0x32 hex 8 8 0x38 hex 3 3 0x33 hex 9 9 0x39 hex 4 4 0x34 hex 0x2A hex 5 5 0x35 hex 0x23 hex Buffers up to 8 keys and outputs keypad data without a facility code like standard Clock and Data card o...

Page 10: ...ng Mode Press to enter The Transmit LED will flash orange Enter the new 3 digit code you wish to set as Facility Code System returns to Transmit Mode You will hear one beep The Program LED will turn o...

Page 11: ...ing the reader from the wall or removing the reader s case Apply power to the reader You now have 10 seconds to enter Programming Mode using the factory default Programming Code 1234 Page 20 06 01 AY...

Reviews: