AY-B9350 User Manual
49
and monitoring pin of the Lock must be also connected to M0. In addition, M0 must be
set to [door open status NO] or [door open status NC] as well.
▶
Tamper Alarm
If this is checked (
), warning sound will be made when the terminal is disassembled.
To apply the setting value, press [OK] button, or press [BACK] button to cancel and to
move to the upper menu.
3.7.4. Lock Setting
Select
[Terminal]
à
[Lock]
in the main menu to display the screen below.
▶
Default setting: same with the setting in the left
screen
▶
Lock 1 option
-
Not use: when it is not used
-
Strike/Auto/successful authentication notice: warning lamp to indicate Strike type,
auto door or authentication success/failure is connected to Lock1
-
Motor lock 1: when a motor lock is connected
▶
Lock 2 option
-
Not use: when it is not used
-
Authentication failure notice: warning lamp to indicate authentication failure is
connected to Lock2
-
Motor lock 2: when a motor lock is connected
▶
Lock 1 Duration (ms)
This is to designate time to give signal when Lock 1 is set to ‘Strike/Auto/successful
authentication notice’. Since it is set to ms unit, set it to 3000 to designate it to 3
seconds. Strike type means time until the door is closed again when the door is open
after authentication.
▶
Lock 2 Duration (ms)
This is to designate time to give signal when Lock 2 is set to ‘authentication failure
notice’. Since it is set to ms unit, set it to 3000 to designate it to 3 seconds.