AY-B9350 User Manual
47
3.7.2. Terminal Option
Select
[Terminal]
à
[Option]
in the main menu to display the screen below.
▶
Default setting: same with the setting in the left
screen
▶
Read Card number
Touch a card on this screen to display card No on
the LCD. Card No according to the setting value can
be searched by changing [card format].
▶
Lock terminal
The function is directly lock or unlock the terminal
by an administrator not from the server program
but at the terminal. If it is checked (
), terminal
will become lock status in which nobody can access
until the administrator release the setting.
▶
Card reader
Card reader can be set to Standard or HID iClass. The
reader will recognize only the setting type of card.
▶
Card format
This is to set method to display card No. Since card No becomes different according to
the setting value as below, set it during initial installation. If it is inevitably changed
during operation, the card must be registered again.
RF card(EM Card) example) card No (5byte): 08h 01h 16h 1Dh D6h
Card format
Card No
Display method
Standard
02207638
Displayed in (3+5)-digit decimal
number
[022 (16h) +07638 (1DD6h) ]
SC card(MIFARE Card) example) card No (4byte): 52h 9Dh 06h E3h
Card format
Card No
Display method
Standard
529D06E3
Displayed in 8-digit hexadecimal
To apply the setting value, press [OK
]
button or press [BACK] button to cancel and to
move to the upper menu.