Programming
20
AY-Q6x60 Series Installation and Programming Manual
Table 2: Programming Menu
Menu Description
Default
1
Selecting Keypad Transmission Format
1 – Single Key, Wiegand 6-Bit (Rosslare Format, Default)
2 – Single Key, Wiegand 6-Bit with Parity Bits
3 – Single Key, Wiegand 8-Bit, Nibbles Complemented
4 – 4 Keys Facility Code, Wiegand 26-Bit
5 – 1 to 5 Keys + Facility Code, Wiegand 26-Bit
6 – 6 Keys BCD and Parity Bits, Wiegand 26-Bit
8 – 1 to 8 Keys BCD, Clock & Data Single Key
*
2
Selecting
MIFARE
Card Transmission Format
1 – Wiegand 26-Bit (default)
2 – Clock & Data
4 – Wiegand 26-Bit with Facility code output
5 – Wiegand 32-Bit
6 – Wiegand 32-Bit reverse output
7 – Wiegand 34-Bit
8 –.Wiegand 40-Bit
*
3
Changing the Programming Code
1234
4
Changing the Facility Code
001
6
Backlight Options
Off
On (Default)
Off until key press when on for 10 seconds
Dimmed until key press when on for 10 seconds
*
0
Return to Factory Default Settings
Reader settings are affected by both keypad programming
and configuration card settings. Note that settings are preset
by the last operation, either configuration card or keypad
programming.