Programming
AC-F/G4x Family Installation and Programming Manual
35
Table 3: Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Mode
Auxiliary Input
Function
Auxiliary Output Activated
by
Auxiliary
Relay
Auxiliary Settings (in seconds)
0
AUX REX
Valid code or AUX REX
N.O.
01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
1
Normal/Secure switch Valid code
N.O.
01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
2
Normal/Secure switch Star button (
*
)
N.O.
01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
3
Normal/Secure switch Tamper event
N.C.
01 to 99 Aux. Relay Release Time
00 Aux. relay tamper activated
4
Normal/Secure switch Direct shunt
N.O.
01 to 99 Shunt time
5
Door Monitor
Shunt
N.C.
01 to 99 maximum Shunt time
6
Door Monitor
Forced door
N.C.
01 to 99 Forced delay
7
Door Monitor
Door ajar
N.C.
01 to 99 Ajar delay
8
LED control – Green
Valid code
N.O.
01 to 99 Aux. Relay Release time
00 Aux. relay toggle
9
LED control – Red
Valid code
N.O.
01 to 99 Aux. Relay Release time
00 Aux. relay toggle