5.3
Changing the Auxiliary Code
The auxiliary code is mainly used as a method to quickly test the
Auxiliary relay during installation. The default 4-digit factory setting
for the auxiliary code is 0852.
For security reasons, when the first user is added to the controller or
the open code is changed, the default auxiliary code is automatically
deleted; non-default codes are not be erased automatically.
•
Auxiliary code does not function in Secure mode.
•
Auxiliary code only works when the auxiliary mode is 0, 1, 8 or 9.
•
Wrong entries: You hear a long beep and the controller returns to
Normal mode.
•
Code 0000 erases and deactivates the auxiliary code.
To change the Auxiliary code:
1.
Enter Programming mode.
2.
Press
2
to enter Menu 2.
The Mode indicator turns orange.
3.
Enter a new Auxiliary code.
4.
The system returns to Normal mode.
You hear three beeps.
The Door indicator turns off.
The Mode indicator turns green.
Mode
Door
Green
Green
Mode
Door
Orange
Mode
Door
Green