Operation
AC-F/G4x Family Installation and Programming Manual
19
4.
Operation
•
In the Operation chapter, “code” refers to a PIN code or proximity
card depending on the unit you have.
•
Memory slots can be a proximity card or PIN code depending on
the unit you have.
4.1
Modes of Operation
The control units have three modes of operation. These are indicated
by the color of the Mode indicator:
4.1.1
Normal Mode (Default)
The mode indicator is green.
In Normal mode, the door is locked until a valid primary code is
presented to the controller.
The controller can only be programmed in Normal mode.
4.1.2
Secure Mode
The mode indicator is red.
Only secure and master users can access the premises in Secure mode.
A secure user must enter a primary and secondary code to gain entry.
Once the primary code has been entered, the Door indicator flashes
green for 10 seconds. During this time, the secondary code must be
entered. A master user only needs to enter his code to gain entry.
4.1.3
Bypass Mode
The mode indicator is orange.
In Bypass mode, access to the premises is dependent on the Lock
Strike relays; that is, if the relay is programmed for failsafe operation
or fail-secure operation.
When the Lock Strike relay is programmed for fail secure operation,
the door is locked until the star button (
*
) is pressed.
When the Lock Strike relay is programmed for failsafe operation, the
door is constantly unlocked.