![Ross Ultripower User Manual Download Page 18](http://html1.mh-extra.com/html/ross/ultripower/ultripower_user-manual_1488937018.webp)
18 • Physical Installation
Ultripower User Guide (v4.0)
3. Connect the first power cable into the PSU socket marked
1
on the ULTRIX-FR2 rear panel.
4. Connect the second power cable into the PSU socket marked
2
on the ULTRIX-FR2 rear panel.
Connecting to an ULTRIX-FR5 Router
Each ULTRIX-FR5 router requires powering from an Ultripower Rack Mount Power Supply Unit.
When using an Ultripower with an ULTRIX-FR5, the ULTRIX-FR5 must run Ultrix software version 3.43 or
higher.
To connect an Ultripower to an ULTRIX-FR5
1. Connect the ends of four power cables to the Ultripower rear panel
OUT
sockets.
2. Connect the free ends of the same power cables to the ULTRIX-FR5 rear panel.
3. Connect an AC power cable to the Ultripower
PSU 1
socket.
4. If Ultripower is fitted with a second power module, connect a second AC power cable to the Ultripower
PSU 2
socket.
Notice
— The ULTRIX-FR2 router automatically powers on when power is applied to Ultripower.
Connect DC cables prior to connecting AC power source to Ultripower. This prevents the ULTRIX-FR2
from trying to draw too much power while only one DC cable is installed.
Notice
— Powering an ULTRIX-FR5 from individual external power supplies is not supported.
Notice
— Ensure that the power cable end with the ferrite bead connects to the Ultripower port.
)
Notice
— The ULTRIX-FR5 automatically powers on when power is applied to Ultripower. Connect DC
cables prior to connecting AC power source to the Ultripower. This prevents the ULTRIX-FR5 from trying
to draw too much power while only one DC cable is installed.
Summary of Contents for Ultripower
Page 1: ...Ultripower User Guide...
Page 6: ......
Page 26: ...26 Configuration Ultripower User Guide v4 0...
Page 36: ...36 Technical Specifications Ultripower User Guide v4 0...