2–8 • Installation
MB-652 User Manual (Iss. 04)
Configuring the DIP Switches
This section briefly summarizes the
DIP Switch
settings on the MB-652.
shows the
DIP Switches in the
UP
position.
Figure 2.3
DIP Switches — Set to the UP Positions
Setting the IP Address
SW1
and
SW2
are used in conjunction with the DashBoard menus to set the IP Address of the
MB-652. Refer to
for DIP Switch positions. For information on configuring the
network settings for your MB-652, refer to the section “
Master Password Override
SW3
is used to override the Master Password and allows a user to reset the Master Password.
Refer to the section “
Using a Master Password in DashBoard
•
UP
— This is the recommended position. A user-specified Master Password is used. The
default password is
password
. It can be changed using DashBoard as outlined in the the
•
DOWN
— This position is used to recover a lost Master Password. The user-specified
password is temporarily ignored, and the default value of
password
is used.
SW4
SW4
is not implemented at this time and should be left in the
UP
position.
Table 2.2 SW1 and SW2 Positions
SW1
Position
SW2
Position
Controlled via
DashBoard
Descriptions
UP
UP
The MB-652 network settings can be set by the user
from the DashBoard
Network
tab
a
. (default)
a.
DHCP Mode is assumed until the user changes the settings in DashBoard.
UP
DOWN
The MB-652 network settings are automatically
assigned (DHCP Mode).
DOWN
UP
The MB-652 IP Address is set to 192.168.2.1 and
the Subnet Mask is set to 255.255.255.0.
DOWN
DOWN
The MB-652 IP Address is set to 10.1.2.1. and the
Subnet Mask is set to 255.255.255.0.