background image

Synergy Display Replacement • 7 

7.

Use a pair of small needle-nose pliers to disconnect the 

3-Pin Display 

Power Cable

 from the power connector on the 

Function Switch

 

Board

.

8.

Remove the retaining screws from each corner of the display and put 
them in a safe place. You will need them to install the new display.

9.

Carefully remove the display from the inside of the control panel.

Installing the Synergy Display

To install the new display, you will need a pair of small needle-nose pliers and a 
Phillips screw driver.

1.

Use a pair of small needle-nose pliers to install the 

3-Pin Display 

Power Connector Cap

 (

30-00104

) into the power connector on the 

Function Switch Board

. The new display does not require a separate 

power connector.

Warning Hazardous Voltage

 — You must install the 3-Pin 

Power Connector Cap to protect the live power pins in the 
connector. Failure to do so could result in personal injury or 
damage to equipment.

2.

Carefully install the new display into the hole that the old display was 
removed from.

3.

Install the retaining screws into each corner of the display. Do not 
over-tighten the screws.

4.

Connect the 

15-Pin Data Cable

 to the data connector on the display. 

Ensure that the orientation of the connector, with relation to pin 1, is 
the same as it was when the cable was connected to the old display.

Caution

 — You must install the 15-Pin Data Cable onto the new display 

in the same orientation as it was removed from the old display. Installing 
the cable incorrectly could damage the display and the switcher.

Summary of Contents for 4800DR-350-01

Page 1: ...Ross Video Limited Synergy Display Replacement Installation Guide DIGITAL PRODUCTION SWITCHER SERIES ...

Page 2: ... 508 455 7 602 446 7 834 886 This product is protected by the following Canadian Patents 2039277 1237518 1127289 Other patents pending Notice The material in this guide is furnished for informational use only It is subject to change without notice and should not be construed as commitment by Ross Video Limited Ross Video Limited assumes no responsibility or liability for errors or inaccuracies tha...

Page 3: ...y cord provides this protective earth connection and must be reliably connected to a facilities protective earth Do not defeat safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit in to your ou...

Page 4: ...impact health and the environment To avoid the potential release of those substances into the environment and to diminish the need for the extraction of natural resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendly and health conscious manner The crossed o...

Page 5: ...ents of the Synergy Display Replacement kit are listed below If any items are missing or damaged contact Ross Video Technical Support Qty Part Item 1 70 00124 Display 1 30 00104 3 Pin Display Power Connector Cap 1 4000ER 033 01 EEPROM U62 Issue 7 ...

Page 6: ...Warning Hazardous Voltage Hazardous voltages are present in the control panel as long as any of the power supplies are connected to the AC power 3 Lift up on the control panel lid to gain access to the control panel tub 4 Identify the board Function Switch Board that the 3 Pin Display Power and 15 Pin Data Cables from the display connect to It is located behind the F1 F6 buttons inside the control...

Page 7: ...h Board The new display does not require a separate power connector Warning Hazardous Voltage You must install the 3 Pin Power Connector Cap to protect the live power pins in the connector Failure to do so could result in personal injury or damage to equipment 2 Carefully install the new display into the hole that the old display was removed from 3 Install the retaining screws into each corner of ...

Page 8: ...power 3 Lift up on the control panel lid to gain access to the control panel tub 4 Remove the screws securing the top of the CPU Enclosure inside the control panel tub and remove the top 5 On the Panel CPU Board 4000AR 033 locate the EEPROM U62 4000ER 033 01 Note the orientation of the EEPROM in the socket The new EEPROM will have to be installed in the same orientation 6 Use the DIP Extraction To...

Page 9: ...splay is different than the old display When the new display is installed you must adjust the contrast so that the menus on the display are visible 1 Press HOME B More B F6 Setup B F1 Display B F1 Large Display 2 Use the middle Contrast knob to select 70 0 or the contrast that best works for you ...

Page 10: ...10 Setting the Display Contrast Notes ...

Page 11: ...Setting the Display Contrast 11 Notes ...

Page 12: ...Company information Related products and full product lines On line catalog News Testimonials PHONE General Business Office and Technical Support 613 652 4886 After Hours Emergency 613 349 0006 Fax 613 652 4425 E MAIL General Information solutions rossvideo com Technical Support techsupport rossvideo com POSTAL SERVICE Ross Video Limited 8 John Street Iroquois Ontario Canada K0E 1K0 Ross Video Inc...