ELECTRICAL CONNECTION
"The installation must conform to the standard directives".
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Wxz|a~
LMMxU²TqRM_`X_rM^XdVZXMTQqMXUX_SZP_TUMV[XZTSPVQiMS`XMR][[UqMSXQRPVQM
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
LMMh`XMXUX_SZP_TUM_VQQX_SPVQMSVMS`XMPQRSTUUTSPVQMR`V]UWM^XMaTWXMYPTM
a socket with a plug with earth, or via an omni pole cut-out
switch compliant to national regulation of destination country.
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
LMMxQqM\]XZPXRMZXfTZWPQfMS`XM[V²XZMR][[UqM_VZWMR`V]UWM^XMZXdXZZXW
to After Sales Service or a qualified technician.
Warning! This appliance must be earthed. In the absence of
adequate earthing you will notice that when touching the
metal parts of your appliance an electrical dispersion can be
felt due to the presence of a radio interference suppressor.
`asa«¬aa©asa«¬a
A power cord is supplied with the Triple which allows it to be
connected only to a power supply of 220-230 V between
phases, or between phase and neutral. Connect to a 10/16
Amp socket.
`asa«¬aa
A power cord is not supplied with this Triple, but it is equipped
with a terminal block that enables you to choose the correct
connection for the particular power supply.
The terminal block is located at the back of the Triple.
To open the terminal block :
. Locate the two tabs on the sides,
gMM[UT_XMS`XMR_ZX²WZPYXZM^UTWXMVQMS`XMdZVQSMVdMS`XMST^iMPQRXZSMPSMMMM
M TQWM[ZXRRMWV²QM
. Lift the cover off.
Terminal block
x 3 bars shunts
To connect :
. unscrew the cable grip,
. pass the cable through the cable grip,
. strip the insulation off the end of the each wire and connect them
to the according to the numbers shown in the table as well as
the "bars shunts".
Example of connection in monophase
1- Put in the
bars shunts
2- Put in
the wires
3- Pass the cable
through the cable grip
}zv~azvxxt}a}z|y}tz|aa ta®|txv ayt}z|a
risks for the power supply cable.
H05VV-F
3 G 2,5 mm2
Monophase
220-230V
~
CABLE
TYPE-AERA
2 Phase
Shunt
1-2
Shunt
2-3
5 Neutral
Shunt
4-5
T Earth
CONNEC-TI
ON TO THE
TERMINAL
BLOCK
To Shunt:
make a
bridge with
a shunt bar
H05RR-F or,
H05VV-F
MMiMaa
H05VV-F or,
H05RR-F
5 G 1,5 mm2
Three phases
220-230V3
~
Three phases
380-415V3N
~
1 Phase
Shunt
1-2
3 Phase
Shunt
3-4
5 Phase
T Earth
1 Phase
2 Phase
3 Phase
5 Neutral
Shunt
4-5
T Earth
L2
L3
INSTALLATION
When the connection operation to the appliance terminals is
finished, tighten the cable clamp and close the cover.
24 GB