background image

00809-0100-4754

English

Rev. BB

Model 333 HART

®

 

Tri-Loop

 HART-to-Analog

Signal Converter

Summary of Contents for 333 HART Tri-Loop

Page 1: ...00809 0100 4754 English Rev BB Model 333 HART Tri Loop HART to Analog Signal Converter ...

Page 2: ......

Page 3: ...um product performance make sure you thoroughly understand the contents before installing using or maintaining this product Within the United States Rosemount Inc has two toll free assistance numbers Customer Central 1 800 999 9307 7 00 a m to 7 00 p m CST Technical support quoting and order related questions North American 1 800 654 7768 24 hours a day Includes Canada Response Center Equipment se...

Page 4: ......

Page 5: ...pply 2 5 Installation Equipment 2 6 Installation Procedure 2 6 1 Review Installation Considerations 2 6 2 Mount Tri Loop on DIN Rail 2 6 3 Wiring 2 6 Configure the Model 3095 MV For Tri loop Operation 2 8 Select Process Variables 2 8 Record Model 3095 MV Units 2 9 Set the Model 3095 MV to Burst Mode 2 10 SECTION 3 Commissioning Overview 3 1 Install The Tri loop Configurator Software 3 1 Minimum Eq...

Page 6: ...issioning the Transmitter A 2 Set the Transmitter to Burst Mode A 2 Set Process Variable Output Order A 2 Special Considerations A 3 Appendix B Introduction B 1 Communicating with a HART Tri Loop B 1 Online Menu B 2 Connections and hardware B 4 Communicator Keys B 6 Action Keys B 6 Function Keys B 7 Alphanumeric and Shift Keys B 7 Fast Key Sequences B 8 Fast Key Sequence Conventions B 8 Fast Key S...

Page 7: ...ield installation This section also explains how to set up the Model 3095 MV to send HART burst commands Section 3 Commissioning explains how to install the HART Tri Loop Configuration software and outlines the main steps to configure a HART Tri Loop Section 4 Troubleshooting provides troubleshooting suggestions for the most common operating problems Section 5 Specifications and Reference Data inc...

Page 8: ...HART Tri Loop HART to Analog Signal Converter 1 2 ...

Page 9: ... Review the HART Tri Loop Product Manual INSTALL THE HART TRI LOOP Mount the Tri Loop to DIN Rail Connect wires from Model 3095 MV to Tri Loop Burst Input Connect Channel 1 Wires from Tri Loop to Control Room Optional Connect Channel 2 and or Channel 3 Wires from Tri Loop to Control Room COMMISSIONING Section 3 Install HART Tri LoopConfigurator onto Your PC DONE No Yes Pass System Test No Check Tr...

Page 10: ...via the Tri Loop DP AP GP PT or flow For each desired analog output a separate pair of wires is installed from the Tri Loop to the control room However Channel 1 wires must be installed and powered for the Tri Loop to operate The initial Model 3095 MV analog output is not altered by the Tri Loop installation UNPACKING THE HART TRI LOOP When custom configuration Tri Loops are shipped the filled out...

Page 11: ...d value is outside the range points the analog output continues to track the input value until reaching the saturation value listed below the output does not exceed the listed saturation value regardless of the measured value For example for values outside the 4 20 range points the output saturates at 3 9 mA or 20 8 mA When the Tri Loop diagnostics detect a Tri Loop failure or a Model 3095 MV malf...

Page 12: ...lded but twisted pairs should be used for best results Wiring should be between 24 12 AWG solid or stranded and not exceed 1 000 feet 305 meters MECHANICAL CONSIDERATIONS The Tri Loop may be rail mounted on any of the DIN rails shown in Figure 2 3 Simply snap the Tri Loop onto the rail in the desired location FIGURE 2 3 DIN Rail Mounting Options SYMMETRICAL 35 X 7 5 MM TOP HAT RAIL SYMMETRICAL 35 ...

Page 13: ...al resistance load is the sum of the resistance of the signal leads and the load resistance of the controller indicator and related pieces NOTE Wiring connections must be made in accordance with local or national installation codes such as the NEC NFPA 70 1 57 40 3 11 79 3 36 86 NOTE Dimensions are in inches millimeters 3095 0810A01A FIGURE 2 5 Power Supply Load Limitations 3051 0103A 1800 1600 14...

Page 14: ...randed and not exceed 1 000 feet 305 meters a Run wire from Tri Loop Channel 1 to control room and secure using screw clamps Be sure to observe proper polarity Include proper loop resistance see page 2 5 b Optional Run wire from Tri Loop Channel 2 to control room and secure using screw clamps Be sure to observe proper polarity Include proper loop resistance see page 2 5 c Optional Run wire from Tr...

Page 15: ...2 6 Tri Loop Wiring Connections Parallel Wiring Model 3095 I S Barrier See Transmitter Manual for I S Barrier Requirements 250 Ω Power Supply Pri mary Sec ondary Ter tiary Fourth Control Inputs NON HAZARDOUS AREA 3095 3095_08A ...

Page 16: ...ut Range Values This screen sets the range values for the primary variable and also allows for reassigning the process variable output order This determines both which process variables are burst by the Model 3095 MV and in which order the variables are sent NOTE The Primary Variable Figure 2 7 is also assigned as the Model 3095 MV 4 20 mA analog output 1 Using the Model 3095 MV EA access the Rang...

Page 17: ...e Pressure Gage Pressure Process Temperature and Flow Applications 1 Using the Model 3095 MV Engineering Assistant access the Transmitter Units Screen 2 If desired change the displayed units Modifying the information on this screen and selecting OK immediately changes the connected transmitter 3 Record in Table 2 1 the selected units for each process variable FIGURE 2 9 Units Screen 3095 30950092 ...

Page 18: ...use of the analog signal Burst mode applies only to the transmission of burst data and does not affect the way other Model 3095 MV data is accessed Transmitter HART Output Burst Mode 1 Using the Model 3095 MV Engineering Assistant access the Burst Mode Screen 2 If required click on the Burst Mode Enabled box 3 Select Dynamic Variables and Current HART Cmd 3 then select OK FIGURE 2 10 Burst Mode Sc...

Page 19: ...STALL THE TRI LOOP CONFIGURATOR SOFTWARE The HART Tri Loop Configurator software package is available with or without the HART modem and connecting cables see page 5 1 for part numbers The complete Configurator package contains four 3 5 in floppy disks one HART modem and a set of cables for connecting the computer to the HART Tri Loop see Figure 3 1 FIGURE 3 1 Tri Loop Configurator Software Equipm...

Page 20: ...er 2 After completion of boot up procedures verify that the computer is in Microsoft Windows If the computer is at the DOS prompt for example C type win return to start Windows 3 Insert the floppy disk containing the first HART Tri Loop Configurator Software into the personal computer disk drive 4 Select File then select Run from the Program Manager to display the Run window Depending on the disk ...

Page 21: ... PC to the Tri Loop When shipped from the factory two quick connect tabs are installed on the Tri Loop COMM ports 1 Connect the computer to the HART Tri Loop see Figure 3 1 and Figure 3 2 a Connect one end of the 9 pin to 9 pin cable to the HART communications port on the personal computer b Connect the other end of the 9 pin to 9 pin cable to the HART modem c Connect one end of the BNC cable to t...

Page 22: ... so that the Tri Loop analog output will be enabled b Optional Repeat step a for Channels 2 and 3 c Click device information enter the desired tag descriptor and message information then select OK 4 Select Configuration Save to Tri Loop to send the configuration to a Tri Loop 5 Select Configuration Open from Tri loop to verify that the configuration was correctly received The Tri Loop configuratio...

Page 23: ... FIGURE 3 4 Tri Loop Wiring Connections Model 3095 I S Barrier See Transmitter Manual for I S Barrier Requirements 250 Ω Power Supply Pri mary Sec ondary Ter tiary Fourth Control Inputs NON HAZARDOUS AREA 3095 3095_08A ...

Page 24: ...5 Configurator Menu Structure HART Tri Loop Configurator File Configuration Tri Loop Diagnostics View Help Connect to Tri Loop Disconnect from Tri Loop Trim Outputs Fixed Outputs HART Preambles Recall Factory Default Trims New Ctrl N Open Ctrl O Save Ctrl S Save As 1 filename tlp Exit Configure Channels Open from Tri Loop Save to Tri Loop Tri Loop Information Error Info Reset Toolbar Status Bar Tr...

Page 25: ...indows 95 Check if HART driver was subsequently over written during a Model 3095 MV Engineering Assistant installation If this has occurred reinstall the Configurator software Check the DEVICEHIGH statement in the CONFIG SYS statement as explained in the Configurator readme file Burst Commands not received from Model 3095 MV Verify the Model 3095 MV is set to Burst Command 3 Check for adequate vol...

Page 26: ...HART Tri Loop HART to Analog Signal Converter 4 2 ...

Page 27: ...minal voltage of 11 42 4 V dc Turn on Time Analog signals will be within specifications five seconds after power is applied to Tri Loop Installation Locations Approved for FM ordinary locations Approved for CSA ordinary locations Model No Part No Description Model 333U 03095 0810 0001 High Alarm Tri Loop Standard Configuration Model 333D 03095 0810 0002 Low Alarm Tri Loop Standard Configuration Mo...

Page 28: ...of span Ambient Temperature Effect per 50 F 28 C 0 15 of span Stability 0 1 of span for 12 months Analog Output Update Tri Loop responds to every HART burst update Typical transmitter burst update rate 0 3 to 0 5 s Tri Loop Response Time after each burst update Channel 1 120 ms Channel 2 220 ms Channel 3 320 ms Total Response Time Typical response time from sensor change to transmitter to Tri Loop...

Page 29: ...__ ___ ___ ___ ___ ___ ___ ___ ___ ___ 16 characters Message ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 32 characters Date ___ ___ ___ ___ ___ ___ ___ dd mmm yy CHANNEL 1 Channel Status select one M Enabled M Disabled Assigned Variable select one 1 M Primary Variable M Secondary Variable M Tertiary Variable M Four...

Page 30: ...NEL 3 Channel Status select one M Enabled M Disabled Assigned Variable select one 1 M Primary Variable M Secondary Variable M Tertiary Variable M Fourth Variable Variable Range Zero 4 mA Value _________________________ 2 Full Scale 20 mA Value ____________________ 2 Variable Units ________________________________________ 2 3 1 Verify process variable assignment for your instrument 2 This informati...

Page 31: ...ackup see Special Considerations on page A 3 Installation Figure A 1 basic installation information For complete installation information and procedures refer to Section 2 Installation FIGURE A 1 HART Tri Loop Installation Flowchart A B B START A Install the Model 3244MV See Rosemount Publication Number 00809 0100 4724 Model 3244MV Installed Unpack the HART Tri Loop Review the HART Tri Loop Produc...

Page 32: ... 0100 4724 Set the Transmitter to Burst Mode 1 From the Home screen Select 1 Device setup 4 Detailed setup 3 Output condition 2 HART output 4 Burst option to prepare to set the transmitter to Burst Mode The communicator displays the Burst option screen 2 Select Process vars crnt The communicator returns to the HART output screen 3 Select 3 Burst mode to prepare to enable Burst Mode The communicato...

Page 33: ...annel on the Tri Loop to include zero For example if you wish the secondary variable of the 3244MV to report differential temperature configure the transmitter accordingly see Set Process Variable Output Order on page A 2 and adjust the corresponding channel of the Tri Loop so one range end point is negative and the other is positive Hot Backup To enable the Hot Backup feature of a Model 3244MV op...

Page 34: ...HART Tri Loop HART to Analog Signal Converter A 4 ...

Page 35: ...x will familiarize you with the HART Communicator but is not meant to replace the HART Communicator product manual COMMUNICATING WITH A HART TRI LOOP The standard configuration for a Model 275 HART Communicator is to search for devices with HART address 0 The HART Tri Loop which is designed to work in conjunction with other HART devices defaults to HART address 1 Therefore before a HART Communicat...

Page 36: ... Rev Fld Dev Rev Software Rev Poll Addr Num Req Preams 1 CONFIGURE CHANNELS 2 RECALL FACTORY TRIM 1 CH1 2 CH2 3 CH3 1 CONFIGURE CH1 2 CONFIGURE CH2 3 CONFIGURE CH3 1 Model 2 Dev ID 3 Tag 4 Date 5 Descriptor 6 Message 7 Final Asmbly Num 8 REVISION s 1 ANALOG OUTPUT 2 HART OUTPUT 1 Model 2 Dev ID 3 Tag 4 Date 5 Descriptor 6 Message 7 Final Asmbly Num 8 REVISION s 1 4mA 2 20mA 3 Other 4 End 1 CONFIGU...

Page 37: ...Loop Test 1 2 1 3 CH2 D A TRIM 1 4 2 Other Output Condition 3 1 1 1 1 3 CH2 Output Condition 3 1 1 2 2 Poll Addr 3 1 2 1 CH3 Calibration 1 3 2 3 Proceed Scaled D A Trim 3 1 1 3 1 1 CH3 D A TRIM 1 4 3 Reset 1 1 2 CH3 Output Condition 3 1 1 2 3 Software Rev Basic Setup 2 3 8 3 Change Scaled D A Trim 3 1 1 3 1 2 Software Rev Detailed Setup 3 2 8 3 Date Basic Setup 2 3 4 Status 1 1 1 Date Detailed Set...

Page 38: ...Optional NiCad Recharger Pack NOTE The HART Communicator needs a minimum of 250 ohms resistance in the loop to function properly The HART Communicator does not measure loop current directly Explosions can result in death or serious injury Do not make connections to the serial port or NiCad recharger jack in an explosive atmosphere Explosions can result in death or serious injury Before connecting ...

Page 39: ...B 5 Appendix B FIGURE B 3 Wiring Connections User Provided Power Supply see page 2 5 3095 3095_2A HART COMMUNICATOR ...

Page 40: ...a device is not found the communicator displays the message No Device Found Press OK If a HART compatible device is found the communicator displays the Online Menu with device ID and tag Directional Keys Use these keys to move the cursor up down left or right The right arrow key also selects menu options and the left arrow key returns to the previous menu HOT Key Use this key to quickly access imp...

Page 41: ...s Figure A 5 perform two functions the fast selection of menu options and data entry FIGURE B 5 HART Communicator Alphanumeric and Shift Keys Data Entry Some menus require data entry Use the alphanumeric and shift keys to enter all alphanumeric information into the HART Communicator If you press an alphanumeric key alone from within an edit menu the bold character in the center of the key appears ...

Page 42: ...ing F3 when it is available If you do not start at the Online Menu the HART fast key sequences will not function properly Use Table B 1 an alphabetical listing of every on line function to find the corresponding HART fast key sequences These codes are applicable only to Level Controller and the HART Communicator MENUS AND FUNCTIONS The HART Communicator is a menu driven system Each screen provides...

Page 43: ...you need to complete the operation If further details are required consult the HART Communicator manual Online Menu The Online Menu can be selected from the Main menu as outlined above or it may appear automatically if the HART Communicator is connected to an active loop and can detect an operating transmitter NOTE The Main menu can be accessed from the Online Menu Press the left arrow action key ...

Page 44: ...rite protected Do you still want to shut off Device is in write protect mode Press YES to turn the HC off and lose the unsent data Display value of variable on hotkey menu Asks whether the value of the variable should be displayed adjacent to its label on the hotkey menu if the item being added to the hotkey menu is a variable Download data from configuration memory to device Prompts user to press...

Page 45: ...nline device disconnected with unsent data RETRY or OK to lose data There is unsent data for a previously connected device Press RETRY to send data or press OK to disconnect and lose unsent data Out of memory for hotkey configuration Delete unnecessary items There is no more memory available to store additional hotkey items Unnecessary items should be deleted to make space available Overwrite exis...

Page 46: ...a for a previously connected device which must be sent or thrown away before connecting to another device Use up down arrows to change contrast Press DONE when done Gives direction to change the contrast of the HC display Value out of range The user entered value is either not within the range for the given type and size of variable or not within the min max specified by the device message occurre...

Page 47: ......

Page 48: ...612 949 7001 1999 Rosemount Inc P R INT E D IN U S A http www rosemount com 00809 0100 4754U Fisher Rosemount Limited Heath Place Bognor Regis West Sussex PO22 9SH England Tel 44 1243 863 121 Fax 44 1243 867 5541 Fisher Rosemount Singapore Pte Ltd 1 Pandan Crescent Singapore 128461 Tel 65 777 8211 Fax 65 777 0947 ...