![Rose electronics ORION XC User Manual Download Page 67](http://html1.mh-extra.com/html/rose-electronics/orion-xc/orion-xc_user-manual_1487128067.webp)
Orion XC Installation and Operations Manual
59
Select between the following settings:
Field
Selection
Description
Function
(01-16)
Connect (P1=CON, P2=CPU)
Set bidirectional connection from console P1 to
CPU P2
Connect Video (P1=CON, P2= CPU)
Set video connection from console P1 to CPU
P2
Disconnect (P1=CON)
Disconnect console P1
Logout User
Logout current user
Set Real CPU (P1=VCPU, P2=RCPU)
Assign a virtual CPU to a real CPU
Set Virtual CON (P1=RCON, P2=VCON)
Assign a real console to a virtual console
Push (P1=CON)
The console’s KVM connection is forwarded to
console P1 and is changed to a video only
connection.
Push Video (P1=CON)
The video signal of the console’s current
connection (KVM or video only) is forwarded to
console P1. The console’s connection remains
unchanged (KVM or video only).
Get (P1=CON)
The console gets a KVM connection to the CPU
that is currently connected to console P1. The
connection of console P1 is changed into a
video only connection.
Get Video (P1=CON)
The console gets a video only connection to the
CPU that is currently connected to console P1.
The connection of console P1 remains
unchanged (KVM or video only).
P1
CON or CPU Device
Name of CON or CPU device
P2
CON or CPU Device
Name of CON or CPU device
Setting up Console Macros through the OSD
Select via
Configuration > CON Macros
in the main menu that console for which a console macro has
to be created.
Figure 50. Setting up Console Macros through OSD