p. 20
Press and hold B2 to SAVE.
9.
8. PRECAUTIONS
Use only properly rated IEC power cord (18AWG 3C SJT) and connect
•
only to compatible voltage supplies (100-240v 50-60hz)
Always use a safety cable to insure the RevoPRO™ cannot fall out of the
•
fixture.
Do not allow power cord to come in contact with the hot body of the
•
luminaire or the rear lamp cap.
Keep fingers clear of moving parts.
•
The metal case of the RevoPRO™ may get very hot after continuous
•
use in a luminaire. Use caution to avoid burns when handling units that
have been in running luminaires.
9. TROUBLESHOOTING
The RevoPRO™ will not fit into the Iris Slot.
1.
Make sure the Friction Lock is in the up (disengaged) position
a.
and that the lock itself is not extending outside the metal case.
The iris slot cover of the luminaire may need to be removed to
b.
allow complete access to the slot. Fully remove the two screws
holding the cover and lift off. Set aside so that the cover can be
reinstalled at a later date.
Installing the RevoPRO™ into the Selecon Pacific Coolight
c.
requires that the guide channel in the side cut of the RevoPRO™
align with the rear guide track in the Pacific’s iris slot.
Note: RevoPRO™ is not compatible with Philips/Selecon SPX or
d.
Leviton LEO.
Threaded Collar will not tighten down on gobo
2.
Check that Threaded Collar is not cross-threaded. Gently un-
a.
screw the Threaded Collar. Reset gobo and re-thread Threaded
Collar following the instructions in Section 4, Installing Gobos.
The projected gobo appears out of round or cut off.
3.
The RevoPRO™ is not properly seated in the luminaire. Remove
a.
RevoPRO™ unit and reinsert making sure that the unit is seated
all the way down in the light.
Note: The Selecon SPX and Leviton Leo luminaires are not cur-
b.
rently compatible with the RevoPRO™ rotator.
RevoPRO™ is powered on but no LED lights appear to indicate that
4.