A display instrument can be attached to this output for visualisation of the heating element temperature.
The ROPEX temperature display ATR-x in its overall characteristics (size, scaling, dynamic behaviour) is optimally
suited for this use and can be used for this, if needed (
section 13 "How to order" on page 59).
With this display, not only can TARGET-ACTUAL comparisons be made, but other criteria can be evaluated, such
as heat-up speed, reaching the setpoint in the specified time, cooling of the heating element, etc.
Beyond that, malfunctions in the control circuit (loose connections, contacting and wiring problems) and possibly
network faults can be observed very well at the display instrument and interpreted accordingly. This applies also
for mutual influencing of several neighbouring control circuits.
In case of alarm, this analogue output is used to output differentiated error messages (
8.11
Booster connection
The controller RES-5006 has a connection for an external switching amplifier (booster) as standard. This connec-
tion (at the terminals 15+16) is required at high primary currents (constant current > 5 A, impulse current > 25 A).
The switching amplifier must be connected in accordance with section 6.7 "Connection diagram with booster con-
nection" on page 14.
The connection line to the external switching amplifier must not exceed a length of 1 m and must be
twisted to avoid EMC interference.
8.12
USB interface for visualisation software ROPEXvisual
®
A USB interface (type micro-USB) is available for system diagnosis and process visualisation. A data connection
can be built up with the ROPEX visualisation software ROPEXvisual
®
over this USB interface.
There is a separate documentation available for the ROPEX visualisation software. The software and the docu-
mentation are available in the
!
12 13 14 15 16 17 18
9
8
6
5
10
11
7
4
3
2
1
P2
P1
Rx
Tx
Rx
Tx
LI
NK
LI
NK
RES-50xx
!
PROCESS CONTROL
EQUIPMENT
E464680
AC
OUTPUT
HEAT
ALARM
BUS FAILURE
DATA EXCHANGE
µC POWER
24VDC POWER
www.
.de
ROPEX
Made in Germany
Vi sual