![Ropex RESISTRON RES-5006 User Manual Download Page 46](http://html1.mh-extra.com/html/ropex/resistron-res-5006/resistron-res-5006_user-manual_1486112046.webp)
Device functions
Page 46
RES-5006
Version 1
8.10
Temperature display (actual value output)
The RES-5006 sends to the terminals 17+18 an analogue signal 0…10 VDC, which is proportional to the real
ACTUAL temperature.
Voltage values:
0 VDC
0 °C
10 VDC
300 °C (ATR-3) or 500 °C (ATR-5), depending on the device configuration.
The correlation between the change in the output voltage and the ACTUAL temperature is linear.
RES-5006
Actual value
output
0…10 VDC
18
17
0 V
Temperature
meter
e.g. ATR-3
0…10 VDC
max. 5 mA
0 - 300 °C range
2
3
4
5
6
7
8
9 10
300
Te
m
p
e
ra
tu
re
T
°C
VDC
Voltage U
60
90
120
150
180
210
240
270
1
20 ºC
“ZERO“
0.66 V
0 - 500 °C range
2
3
4
5
6
7
8
9 10
500
100
150
200
250
300
350
400
450
°C
VDC
Te
m
p
e
ra
tu
re
T
Voltage U
1
0 4 V
.
20 ºC
“ZERO“