3
these dimensions cannot be achieved, the strength of the frame may be reduced, which could also reduce its
spacing capacity. If this occurs, additional engineering review is recommended.
The cantilever is designed to allow front-to-back adjustment during installation. The cantilever distance can range
from 1’-1” to a maximum of 1’-6”. Frames should be assembled so that when they are adjusted, the maximum
cantilever on any given frame is 1’-6” or less.
Tubes (labeled “H”, “V” and “D”, for horizontal, vertical and diagonal) are pre-cut to fit the frame per dimension
parameters shown in the drawing, and include crimped ends where shown. If any dimensions in the frame are
increased, the tubes may be too short to fit.
F
IGURE
1