User-defined mode (Program mode)
Select this application mode with the key
T12
. Here, 20 user-defined pro-
grams can be set and saved. The programs 1-20 were loaded with pre-
sets by factory (4.0 Nm³/h total air, 60% powder output, 80 kV high volt-
age, 80 µA spray current, 0.2 Nm³/h electrode rinsing air and 1.0 Nm³/h
fluidizing air).
Setting powder output and powder cloud
The powder output is dependent on the selected powder amount (in %)
and the adjusted total air volume.
Setting the total air volume
1. Adjust the total air volume with the keys
T3/T4
(see also the
injector operating manual)
-
Adjust the total air volume according to the correspond-
ing coating requests
Setting the powder output
1. Adjust the powder output volume (e.g. according to the de-
sired coating thickness)
-
The selection takes place with the keys
T1/T2
on the
control unit or with the
+/-
keys on the rear side of the
powder gun (PROTON II gun type). Factory default
setting of 60% is recommended for initial spraying. The
total air volume is thereby kept constant automatically by
the control unit
2. Check the powder fluidizing in the hopper and ensure you
have a small simmer or very low boiling action
3. Point the gun into the booth, press the gun trigger and visu-
ally check the powder output
Note:
As a factory default value, a powder rate of 60% and a total air vol-
ume of 4 Nm³/h are recommended. By inserting values, which the
equipment cannot convert, the operator is made aware by flashing
of the appropriate display and a temporary out of range message!
Setting the electrode rinsing air
1. Adjust the correct electrode rinsing air according to the ap-
plied nozzles (deflector plate, flat jet nozzle), see note below
for default/starting values
-
Press key
T9
(
SELECT
)
The second display level is switched over
-
Press keys
T7/T8
:
Here, the corresponding air volume value is entered
-
If this display level is not operated for 3 seconds, the first
display level is switched over independently