background image

 

 

 

4802-7536C 

15 November 2021 

RS-500 WIC, RS-500M, and RS-600M Door Training Guide 

NOTICE:

 If you encounter any issues that cannot be resolved using the information in this document, contact 

RollSeal at 1-888-765-5732. 

Section 1: Comparison of RS-500 Walk-In Cooler (WIC) Door and RS-500M/RS-600M Door 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Section 2: Controller Enclosure Comparison 

 

 

Summary of Contents for RS-500 WIC

Page 1: ...aining Guide NOTICE If you encounter any issues that cannot be resolved using the information in this document contact RollSeal at 1 888 765 5732 Section 1 Comparison of RS 500 Walk In Cooler WIC Door...

Page 2: ...4802 7536C 2 15 November 2021 RS 500 WIC RS 500M and RS 600M Door Training Guide Section 3 Door Wiring Diagrams 3 1 RS 500 WIC Door...

Page 3: ...4802 7536C 3 15 November 2021 RS 500 WIC RS 500M and RS 600M Door Training Guide 3 2 RS 500M RS 600M Door...

Page 4: ...r 5 seconds to disengage Jog Mode The controller will return to normal operating mode and the display will show the Actual Position The controller will not know the door s exact position so it will di...

Page 5: ...5 If P24 0 P26 CMS Off Time 10 If P24 0 PS1 Setup Door Limits PS2 Set Open Limit PS3 Set Close Limit Section 6 Setting Limits PS1 Change Program Limits This can be set to Yes or No To change the Open...

Page 6: ...Closing Over Speed Fault FE RS 500M RS 600M Door Code Condition Panel Movement Problem Area Recommended Action s EO1 Opening Home Switch Tripped Home Switch Check wiring Ensure Home switch arm is ful...

Page 7: ...d determine whether the door will jog If the door jogs the door assembly brake relay is defective If the door does not jog contact RollSeal 1 888 765 5732 while remaining at the door o If the door jog...

Page 8: ...00 WIC doors and RS 500M RS 600M doors RS 500 WIC doors use a FLY sensor as an auxiliary safety RS 500M RS 600M doors use an egress strap as an auxiliary safety 1 If the switch lights up but does not...

Page 9: ...ondition Possible Cause s Solid Green Slowly Flashing Green Operation is normal N A Quickly Flashing Green Current is over load Drive is operating between 120 and 200 of rated load Slowly Flashing Red...

Page 10: ...turn fan is not operational Supply Fan L ON Green The supply fan is running at the designated RPM Supply Fan L FAIL Red The supply fan is not operational Heat ON Green At least one of the two fans is...