background image

 

 

 

4802-7536C 

15 November 2021 

RS-500 WIC, RS-500M, and RS-600M Door Training Guide 

Error 

Switch LED Error Code 

Description 

Primary Safety 

PS 

Safety Beam (Emitter and Receiver Near Bottoms of Tracks) 

Auxiliary Safety 

AS 

Aux. Safety Sensor (WIC/WIF – Motion Sensor in Head Unit; RS-500M/600M - Egress Strap) 

Leading Edge 

LE 

Leading Edge Switch (Mechanical Switch in Head Unit) 

Home Switch 

HS 

Home Sensor (Fixed-field Sensor in Head Unit) 

Feedback Error 

FE 

Encoder (Error with Encoder Counting or Door Not Operating) 

Open Switch 

OP 

Open Activation 

Close Switch 

CL 

Close Activation 

Stop Switch 

ST 

Stop Switch (if Present) 

 

NOTICE:

 Safety beams are the primary safety for both RS-500 WIC doors and RS-500M/RS-600M doors. RS-500 WIC doors use a 

FLY sensor as an auxiliary safety. RS-500M/RS-600M doors use an egress strap as an auxiliary safety. 

1.

 

If the switch lights up but does not operate when pressed, remove the right track clad and ensure the [5] switch 

board nuts are tight. 

2.

 

In case of a Home or Leading switch error: 

a.

 

Check the switch by hand to ensure its operation is mechanically correct. 

b.

 

Ensure all switch arms are in the Down position. 

c.

 

Ensure no brackets are bent and the switch arm is contacting the panel. 

d.

 

Ensure the Home switch power indicator light is on at all times. 

Section 9: Drive Board Diagnostics LEDs 

The drive’s condition is indicated by a pair of LEDs (Power [“PWR”] and Status [“ST”]) on the drive board. The LEDs may 

remain solid, flash slowly (on one second; off one second), or flash quickly (on 0.25 seconds; off 0.25 seconds). 

 

 

 

Summary of Contents for RS-500 WIC

Page 1: ...aining Guide NOTICE If you encounter any issues that cannot be resolved using the information in this document contact RollSeal at 1 888 765 5732 Section 1 Comparison of RS 500 Walk In Cooler WIC Door...

Page 2: ...4802 7536C 2 15 November 2021 RS 500 WIC RS 500M and RS 600M Door Training Guide Section 3 Door Wiring Diagrams 3 1 RS 500 WIC Door...

Page 3: ...4802 7536C 3 15 November 2021 RS 500 WIC RS 500M and RS 600M Door Training Guide 3 2 RS 500M RS 600M Door...

Page 4: ...r 5 seconds to disengage Jog Mode The controller will return to normal operating mode and the display will show the Actual Position The controller will not know the door s exact position so it will di...

Page 5: ...5 If P24 0 P26 CMS Off Time 10 If P24 0 PS1 Setup Door Limits PS2 Set Open Limit PS3 Set Close Limit Section 6 Setting Limits PS1 Change Program Limits This can be set to Yes or No To change the Open...

Page 6: ...Closing Over Speed Fault FE RS 500M RS 600M Door Code Condition Panel Movement Problem Area Recommended Action s EO1 Opening Home Switch Tripped Home Switch Check wiring Ensure Home switch arm is ful...

Page 7: ...d determine whether the door will jog If the door jogs the door assembly brake relay is defective If the door does not jog contact RollSeal 1 888 765 5732 while remaining at the door o If the door jog...

Page 8: ...00 WIC doors and RS 500M RS 600M doors RS 500 WIC doors use a FLY sensor as an auxiliary safety RS 500M RS 600M doors use an egress strap as an auxiliary safety 1 If the switch lights up but does not...

Page 9: ...ondition Possible Cause s Solid Green Slowly Flashing Green Operation is normal N A Quickly Flashing Green Current is over load Drive is operating between 120 and 200 of rated load Slowly Flashing Red...

Page 10: ...turn fan is not operational Supply Fan L ON Green The supply fan is running at the designated RPM Supply Fan L FAIL Red The supply fan is not operational Heat ON Green At least one of the two fans is...

Reviews: