15
RolliBot RolliCool Mini-Split AC User Manual
3.4 – Separating the Coupler
If needed, the Indoor and Outdoor Units can be disconnected from one another in case any
adjustments or maintenance is needed. Before separating the coupler from the unit, turn off the
RolliCool, disconnect it from any power supply and wait at least 5 minutes.
Never separate the coupler while the unit is on.
Step 1.
Unscrew the screw at the right side of the
cover. Push the button at the right side of the
cover and pull it away from the unit to remove
it.
Step 2.
Slowly open the latch and hold the Coolant
Lines so that they’re straight. Note, the unit
may emit a chugging sound due to the
refrigerant; this is normal.
Step 3.
Disconnect the power cable from the inside
of the unit. Lift the Coolant Lines up and away
from the unit to remove it.
Step 4.
Insert the rubber stopper into the end of the
Coupler to prevent leakage.
Cover
Keep the Coolant
Lines straight
Latch
Power Cable
Rubber Cap