background image

12

Rollerdor RD20X2ELL Control Box,  Edition 2022/1

OTHER POSSIBLE ISSUES

LED IN THE FRONT COVER

ON:

 safety alarm activate (see the specific alarm).

OFF:

 normal functioning.

1 flash - pause:

 keypad locked (holiday mode).

Flashing slowly:

 low batteries in the bottom slat 

transmitter (TCSP)

Led ON:

 The control unit is powered.

RADIO CARD (MASTER)

Flashing:

 normal functioning.

ON:

 transmission error or drained batteries.

ON:

 activated safety alarm, transmission error or

drained batteries.

OFF:

 normal functioning.

Not used.

Summary of Contents for RD20X2ELL

Page 1: ...Rollerdor RD20X2ELL Control Box Edition 2022 1 Installation Guide for Roller Garage Doors RD20X2ELL Control Box Edition 2022 1...

Page 2: ...2 Pictures are for illustration purposes only connector blocks are not provided and further fittings may be required fig 1 fig 2...

Page 3: ...e 4 fixings drill and secure the unit to the wall fig 2 4 If you have a safety brake with a cable then run the two core cable from the safety brake end across to the same end as the receiver box makin...

Page 4: ...4 2 ELECTRICAL CONNECTIONS Pictures are for illustration purposes only connector blocks are not provided and further fittings may be required...

Page 5: ...ty 4 Test safety edge connection the RED LED on the base rail should be out slide dip switch 2 into the ON position you now have 30 seconds to test the connection by squeezing the base rail rubber whe...

Page 6: ...tly flashing then the base rail unit has been paired move onto Programming Transmitter s section if LED 3 is flashing then continue to Programming Base Rail section 1 Push and hold the red P1 programm...

Page 7: ...ers 2 Channel 1 Press P1 PROG button two times on last press HOLD causing the buzzer to emit a continuous sound 2 Whilst P1 PROG is still pressed press the top button on the transmitter you will hear...

Page 8: ...hear a continuous beep from the control box whilst holding the button press and hold Number 1 on the keypad the continuous beep will change to faster beep on hearing this release all buttons and the k...

Page 9: ...ain is supplied with stops at each end to stop an uneven floor having an effect fig 13 but if the curtain reopens having hit the floor the safety edge exclusion should be set to turn off the edge 50mm...

Page 10: ...losed and the courtesy light has gone out use the manual crank to wind the door open a little you may need to lift and shake the base rail to activate as the smooth motion of winding may not trigger t...

Page 11: ...required TROUBLESHOOTING WHAT TO DO IF ACOUSTIC SIGNALS FROM THE CONTROL UNIT Press P1 eight times and keep it pressed The buzzer emits a continuous sound Activate the shock sensor Once the memorisati...

Page 12: ...sh pause keypad locked holiday mode Flashing slowly low batteries in the bottom slat transmitter TCSP Led ON The control unit is powered RADIO CARD MASTER Flashing normal functioning ON transmission e...

Page 13: ...orwich Norfolk NR5 9JD 44 0 1603 743215 sales rollerdor net www rollerdor net Company Registration Number 10676267 Registered Office Address Rollerdor Ltd Bankside 300 Peachman Way Broadland Business...