Important: Never change the diameter of the injectors.
Gas category table, according to the country of destination of the appliance.
Injector N°
Gas
Pressures
Diameter
Injector n°1
G30 / G31
Butane/Propane
28
-
30/37
90/100
Injector n°2
G30 / G31
Butane/Propane
50
85/100
Injector n°3
G20 / G25
Natural gas
20
-
25
135/100
Injector n°4
G25 Natural gas
25
135/100
Injector n°5
G25 Natural gas
20
135/100
Injector n°6
G31 Propane
50
85/100
Air adjustment
Injectors were conceived to avoid any air adjustments and that whatever the gas you
use.
Country of destination
Category
Gas
Pressures
Diameter of injector
France/Luxembourg
II2E+3+
II2E+3B/P
G20/G25
G30/G31
G20/G25
G30/G31
20/25
28
-
30/37
20/25
50
135
90
135
85
Germany
II2E+3B/P
G20 /G25
G30/G31
20
50
135
85
Austria
II2H3B/P
G20
G30/G31
20
50
135
85
Belgium
I3+
I2E
G30/G31
G20/G25
28
-
30/37
20/25
90
135
Sweden, Denmark,
Finland
II2H3B/P
G20
G30/G31
20
28
-
30/30
135
90
Spain
II2H3+
II2H3P
G20
G30/G31
G20
G31
20
28
-
30/37
20
50
135
90
135
85
Netherlands
II2L3B/P
II2L3P
G25
G30/G31
G25
G31
25
28
-
30/37
25
50
135
90
135
85
Norway
I3B/P
G30/G31
28
-
30/30
90
Iceland/Greece/United
Kingdom/Italy/Portugal
II2H3+
G20
G30/G31
20
28
-
30/37
135
90
Poland
II2E3P
G20/25
G31
20
37
135
90
16