background image

| Automate

 Installation Instructions | DC Power Distribution Panel 

ROLLEASE ACMEDA

WARNING: Important safety instructions to be read before installation.

Incorrect installation can lead to serious injury, which may result in death and will void manufacturer’s liability and warranty.

AVERTISSEMENT: Consignes de sécurité importantes à lire avant l’installation.

Une installation incorrecte peut entraîner des blessures graves, voire mortelles, et annule la responsabilité et la garantie du 
fabricant.

CAUTION

• 

Do not expose to moisture or extreme environments.

• 

Do not allow children to play with this device.

• 

Use or modification outside the scope of this instruction manual will void warranty.

• 

Installation and setup to be performed by a suitably qualified installer.

• 

For use with DC powered motorized shading devices.

• 

Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.

• 

Keep clear when in operation.

• 

For use with DC motors only (NOT suitable for charging Li-ion Battery powered motors).

• 

Do not cut power cables

• 

Do not drill into motor body or distribution panel.

• 

The routing of cable through walls shall be protected by isolating bushing or grommets.

• 

Ensure motor power cable and aerial is clear and protected from moving parts.

• 

If cable or power connector is damaged do not use.

MISE EN GARDE

• 

Ne pas exposer à l’humidité ou à des environnements extrêmes.

• 

Ne laissez pas les enfants jouer avec cet appareil.

• 

Toute utilisation ou modification en dehors de ce manuel d’instructions annulera la garantie.

• 

L’installation et la configuration doivent être effectuées par un installateur qualifié.

• 

À utiliser avec les dispositifs d’ombrage motorisés alimentés en courant continu.

• 

Inspectez fréquemment l’utilisation non conforme. Ne pas utiliser si une réparation ou un réglage est nécessaire.

• 

Restez à l’écart lors de l’exploitation.

• 

À utiliser uniquement avec des moteurs à courant continu (NE convient PAS pour charger des moteurs alimentés   

 

par batterie Li-ion).

• 

Ne pas couper les câbles d’alimentation

• 

Ne percez pas dans le corps du moteur ou le panneau de distribution.

• 

Le passage des câbles à travers les murs doit être protégé en isolant les traversées ou les passe-câbles.

• 

Assurez-vous que le câble d’alimentation du moteur et l’antenne sont dégagés et protégés des pièces mobiles.

• 

Si le câble ou le connecteur d’alimentation est endommagé, ne l’utilisez pas.

OUT 

1O

UT 

2O

UT 

3O

UT 4 

OUT 

5O

UT 

6O

UT 

7O

UT 8 

O

UT 9 

OUT 10

OUT 11

OUT 12

OUT 13

OUT 14

OUT 15

OUT 16

OUT 17

OUT 18

OUT 

1O

UT 

2O

UT 

3O

UT 4 

OUT 

5O

UT 

6O

UT 

7O

UT 8 

O

UT 9 

OUT 10

OUT 11

OUT 12

OUT 13

OUT 14

OUT 15

OUT 16

OUT 17

OUT 18

SAFETY INSTRUCTIONS

Summary of Contents for AUTOMATE MT03-0301-411005

Page 1: ...wer for up to 18 separate ARC DC motors Higher 15V output allows for greater cable lengths from motor to power panel freeing up routing options within an installation Removes the need for multiple ind...

Page 2: ...Table Maximum Lengths 6 3 2 Motor Power Distribution Setup 7 3 3 Wiring Diagram Individual Connection MTDCRF28 25 8 3 4 Wiring Diagram Two Wire Entry Connections in Parallel MTDCRF45 35 8 3 5 JST Conn...

Page 3: ...t 5 18 Individual fuses for channel protection Quick Blow Fuse 3 15A M205 6 18 Channel Status LEDs 7 Plastic Plugs For cable routing 8 Potentiometer for output voltage adjustment 9 Cooling fan 10 Term...

Page 4: ...ial is clear and protected from moving parts If cable or power connector is damaged do not use MISE EN GARDE Ne pas exposer l humidit ou des environnements extr mes Ne laissez pas les enfants jouer av...

Page 5: ...e s curit importantes lire avant utilisation Pour la s curit des personnes il est important de suivre les instructions fournies Les personnes y compris les enfants dont les capacit s physiques sensori...

Page 6: ...18 AWG 16 AWG N A 18 AWG 18 AWG N A 100m 18 AWG 16 AWG N A 16 AWG 18 AWG N A 105m 18 AWG 16 AWG N A 16 AWG 18 AWG N A 110m 18 AWG 16 AWG N A 16 AWG 18 AWG N A 115m 18 AWG 16 AWG N A 16 AWG 18 AWG N A...

Page 7: ...re power applies to the distribution panel Use of two parallel connections ensures the power supply is not overloaded during larger motor operation OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT...

Page 8: ...d viter de surcharger le circuit d alimentation et d endommager le tableau de distribution Due to 1 33A limit per channel working current can be doubled to 2 66A with parallel configuration as shown...

Page 9: ...que soient en place couvrant les borniers V rifiez que les borniers de connexion du moteur page 2 ne pr sentent pas de fils desserr s ainsi que la polarit connexion voir ci dessous WIRING POLARITY FRO...

Page 10: ...e the appropriate repairs and replace the fuse with a 3 15A M205 quick blow fuse In order to replace fuse carefully pry the fuse out of the plastic cradle using a small tool such as a small screwdrive...

Page 11: ...Power is supplied to panel but exterior LED is not lit Open panel and switch internal power switch to ON position A C terminal block wiring is incorrect CAUTION Do NOT attempt to rewire mains power t...

Page 12: ...OLLEASE ACMEDA APPENDIX CONTENTS A APPENDIX 1 DC POWER DIST PANEL PULSE 2 0 HUB APP A APPENDIX 1 DC POWER DIST PANEL PULSE 2 0 HUB APP 12 A 1 PULSE 2 0 HUB ADDITIONAL INSTALLATION SET UP INSTRUCTIONS...

Page 13: ...ia the Trim Pot located on the converter within the Distribution Panel NOTE Adjusted Output voltage is applicable to all 18 Channels WARNING DANGEROUS LIVE VOLTAGE DO NOT ATTEMPT UNLESS QUALIFIED TO O...

Page 14: ...stribution est connect au secteur 120V 240V Ne pas tenter d panner le panneau sans d abord couper l alimentation et attendre un certain temps de 5 minutes A 3 TROUBLE SHOOTING PROBLEM CAUSE REMEDY Mot...

Page 15: ...15 Automate Installation Instructions DC Power Distribution Panel ROLLEASE ACMEDA A 4 NOTES...

Page 16: ...Broadmeadows VIC 3047 T 61 3 9355 0100 F 61 3 9355 0110 ROLLEASE ACMEDA USA 7th Floor 750 East Main Street Stamford CT 06902 6320 T 1 800 552 5100 F 1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca De...

Reviews: