Product Specification
EVQROCM-01-V03-R0 Installation and Operation Manual
Quantum:EV OpenCharge
January 2022
Page
6
of
25
Electrical Specification
Product Code
OCPP0410
OCPP0411
OCPP0420
OCPP0421
OCPP0425
C
Chhaarrg
giinng
g S
So
occkkeett((ss))
1x Type 2
(IEC 62196)
2x Type 2
(IEC 62196)
4x Type 2
(IEC 62196)
AC Charging Output
1 x 3.6kW
(16A)
1 x 7.2kW
(32A)
2 x 3.6kW
(16A)
2 x 7.2kW
(32A)
4 x 7.2kW
(32A)
Charge Protocol
Mode 3
AC Overload Protection
1x C20A MCB
1x C40A MCB
2x C20A MCBs
2x C40A MCBs
4x C40A MCBs
A
AC
C &
& D
DC
C F
Faauulltt P
Prro
otteeccttiio
onn
1x Type B RCD
2x Type B RCDs
4x Type B RCDs
Input Supply
1x 16A 230V
AC/50Hz
(Single Phase)
1x 32A 230V
AC/50Hz
(Single Phase)
1x 32A 230V
AC/50Hz
(Single Phase)
1x 63A 230V
AC/50Hz
(Single Phase)
2x 63A 230V
AC/50Hz
(Single Phase)
Cable Terminals
3x 50 mm
(2x) 3x 50 mm*
Communications
GPRS (Recommended signal strength of 14 CSQ or better), or
RJ45 ethernet connection
2x RJ45
ethernet
connections
Operating Temperature
-30°C to +50°C
*Alternative cable terminal options available upon request
Product Code
OCPP0412
OCPP0410
OCPP0422
OCPP0423
C
Chhaarrg
giinng
g S
So
occkkeett((ss))
1x Type 2 (IEC 62196)
2x Type 2 (IEC 62196)
AC Charging Output
1 x 11kW
(16A)
1 x 22kW
(32A)
2 x 11kW
(16A)
2 x 22kW
(32A)
Charge Protocol
Mode 3
AC Overload Protection
1x C20A MCB
1x C40A MCB
2x C20A MCBs
2x C40A MCBs
AC & DC Fault Protection
1x Type B RCD
2x Type B RCDs
Input Supply
1x 16A 400VAC
50Hz (3 Phase)
1x 32A 400VAC
50Hz (3 Phase)
1x 32A 400VAC
50Hz (3 Phase)
1x 63A 400VAC
50Hz (3 Phase)
Cable Terminals
5x 50 mm
Communications
GPRS (Recommended signal strength of 14 CSQ or better)
RJ45 ethernet connection
Operating Temperature
-30°C to +50°C
Summary of Contents for OCPP0410