Contents

Product Support

2

Safety

3

Safety Advice within this Manual

3

Product Overview

4

Features

4

Product Specification

5

Physical Specification

5

Electrical Specification

6

Certifications and Compliances

7

Options and Accessories

7

Unpacking

7

Standard Contents

7

Labelling

8

Information Labels

8

Installation

9

Before Installation

9

Base Installation – If Supplied:

9

If a Base is Not Supplied:

10

Schematics

10

Install the Charger

14

Commissioning

15

Commissioning with VendElectric

15

After Installation

15

Operation

16

VendElectric EV Driver Application

16

Status Indicator Guide

16

To End a Charging Session

17

Charging Cables and Sockets

17

Maintenance

18

External Cleaning and Inspection

18

Suggested Inspection and Testing

19

VendElectric Host’s Guide

20

VendElectric Installer’s Guide

21

Product Support

x

Please go to www.rolecserv.com and refer to the product support area.

x

For installation assistance and advice, contact your preferred electrical 

installer.

Product Support

AutoCharge:EV OpenCharge

EVACOCM-01-V02-R3 Installation and Operation Manual

Page 

1

of 

21

December 2021

Amendments

Amendment 

Number

Details

Date

Ver 1, Rev 0 New Document.

September

2020

Ver 2, Rev 0 Amended to include VendElectric details.

December 

2020

Ver 2, Rev 1

Amendment to Host and Installer Guides

Amendment to Specification Wording

Addition of Connector Type Label

April 2021

Ver 2, Rev 2 Correction to Compliances Table

August 

2021

Ver 2, Rev 3 Consolidation of changes across all EV charger manuals

December 

2021

Product:

AutoCharge:EV OpenCharge

Applicable Models:

Single Phase

OCPP0010

OCPP0011

OCPP0020

OCPP0021

Three Phase Superfast

OCPP0012 

OCPP0013

OCPP0022

OCPP0023

Document Type:

Installation and Operation Manual

Document Code:

EVACOCM-01-V02-R3

Language:

UK English (Original)

Date Published:

December 2021

Rolec Services Ltd are the publishers of this document and own the rights to use the text, images and all technical 

content contained within. Content supplied by third parties / partner organisations remains the property of that 

organisation and is used by agreement with the supplier.

Rolec Services Ltd exercise care to ensure content is as accurate as possible at the time of publication. However, no 

guarantee of accuracy should be inferred.

Rolec Services Ltd, Ralphs Lane, Boston, Lincolnshire PE20 1QU. United Kingdom.

+44 (0) 1205 724754

[email protected]

Summary of Contents for OCPP0010

Page 1: ...AUTOCHARGE EV EV OPENCHARGE GPRS Ethernet Communication INSTALLATION OPERATION MANUAL MODELS SINGLE PHASE OCPP0010 1 X 3 6kW OCPP0011 1 X 7 2kW OCPP0020 2 X 3 6kW OCPP0021 2 X 7 2kW 3 PHASE OCPP0012 1...

Page 2: ...hase OCPP0010 OCPP0011 OCPP0020 OCPP0021 Three Phase Superfast OCPP0012 OCPP0013 OCPP0022 OCPP0023 Document Type Installation and Operation Manual Document Code EVACOCM 01 V02 R3 Language UK English O...

Page 3: ...nstallation 9 Base Installation If Supplied 9 If a Base is Not Supplied 10 Schematics 10 Install the Charger 14 Commissioning 15 Commissioning with VendElectric 15 After Installation 15 Operation 16 V...

Page 4: ...do so by the manufacturer x Do NOT attempt to repair the equipment unless specifically instructed to do so by the manufacturer x To maintain electrical safety the body enclosure of the product access...

Page 5: ...ge OCPP Superfast 1x 11kW 16A Type 2 socket OCPP0013 AutoCharge EV OpenCharge OCPP Superfast 1x 22kW 32A Type 2 socket OCPP0022 AutoCharge EV OpenCharge OCPP Superfast 2x 11kW 16A Type 2 sockets OCPP0...

Page 6: ...mensions 1275 x 323 x 270 mm HxWxD Material Steel Enclosure Mass 24 5kg Operating Temperature 30 C to 50 C Operating Humidity Range 5 to 95 Figure 1 General Arrangement and Dimensions 2 socket model s...

Page 7: ...0Hz Single Phase Cable Terminals 3x 50mm Single Phase Communications GPRS Requires a signal strength of 14 CSQ or better or Requires an RJ45 ethernet cable Operating Temperature 30 C 50 C Product Code...

Page 8: ...n x Enclosure IP54 Socket IP54 BS EN 60529 1992 A2 2013 x Enclosure IK10 BS EN 62262 Plug s Socket s x BS EN 62196 1 2014 BS EN 62196 2 2017 Fire Rating x UL94 Flame Rating at V2 for 1 5mm and 3 0mm R...

Page 9: ...nt enclosure Labels may be in the form of adhesive stickers plates and or moulded into the surface of components Information Labels Figure 2 Typical Product Rating Label Figure 3 Typical Fascia Label...

Page 10: ...arger and any accessories have not been damaged in transit NOTE Items damaged in transit must first be reported to the courier and then to the supplier Where possible photographic evidence of package...

Page 11: ...Single Socket AutoCharge EV OpenCharge Schematic ACEN0095 C20 1 2 O OFF ACEQ0040 C6 2 N N 1 N N T A2 A1 14 11 12 WHITE J602 X1 X603 X601 X602 X600 1 7 6 2 4 5 1 3 4 6 WHITE 1 2 3 14 11 25 E CP PP N L3...

Page 12: ...NG CONTROLLER RHS VIEW GREENFLUX SMART CHARGING CONTROLLER LHS VIEW 2 1 10 8 13 8V Max 2A Max 24Watt OUTPUT 12V 2A E CP PP N L3 L2 L1 V N INPUT 100 240VAC 0 88A 50 60Hz A1 L V 11 A2 12 14 3 2 1 SOCKET...

Page 13: ...50Hz 1 3 5 7 24 23 21 20 2 4 6 8 ACEQ0040 C6 2 N N 1 N N T ACEO0240 63A 30mA 400 415V 50 60 Hz N 1 3 5 N 2 4 6 LIVE 1 LIVE 2 LIVE 3 NEUTRAL EARTH A1 A2 WHITE J602 X1 X603 X601 X602 X600 1 7 6 2 4 5 1...

Page 14: ...12V 2A E CP PP N L3 L2 L1 V N INPUT 100 240VAC 0 88A 50 60Hz A1 L V 11 A2 12 14 3 2 1 SNUBBER SOCKET 1 SOCKET 2 A B 1000imp kWh DTS353F 2 EN50470 1 3 kWh 25 C to 55 C 3X230 400V 0 25 5 80 A 50Hz 1 3 5...

Page 15: ...tallation IMPORTANT NOTE It is the responsibility of the installing engineer to satisfy themselves that all cable terminations throughout this product are secure and tight and have not become loose st...

Page 16: ...reliminary tasks listed in the Host s Guide shown at the end of this manual must have been performed by the customer Host before commissioning can proceed 2 To complete commissioning refer to the Inst...

Page 17: ...r to the EV Driver App User Guide included within the charger packaging Status Indicator Guide Flashing blue light Socket Available Flashing green light Socket Available for Plug and Go charging optio...

Page 18: ...ions 3 Charging cables should be routed between the charger and the vehicle so as not to cause an obstruction or trip hazard 4 Charging cables must NOT be left connected to the charger when not in use...

Page 19: ...eer in accordance with applicable regulations for the region of use A typical maintenance inspection and testing schedule is provided on the next page This schedule alternates on a quarterly basis bet...

Page 20: ...sical damage x All warning labels present and legible x Status Indicators operating and displaying correct status x If installed check the condition of the charging socket contacts and socket flap x I...

Page 21: ...vises the Client how this can be done during the handover process We also recommend that you consider entering a service and support agreement with your preferred Installer to ensure you are covered f...

Page 22: ...3 CONTACT US 4 COMPLETE For more information call 01205 725765 Email support vendelectric com Or visit vendelectric com As a part of its services VendElectric will routinely monitor the connectivity a...

Page 23: ......

Page 24: ...THE UK S LEADING MANUFACTURER OF EV CHARGING POINTS t 01205 724773 e enquiries rolecserv co uk www rolecserv com...

Reviews: