Connecting Peripheral Devices

 

The S-4000M comes with five ferrite cores. Attach these to all REAC cables you connect to the S-4000M. Clamp the ferrite core 
onto the cable at a location near the plug at the end of the cable, pressing down on the ferrite core until it clicks closed.

 

fig.fit-ferrite-core.eps

 

* When attaching a ferrite core, be careful to avoid pinching your fingers.

* When connecting a REAC device, use a cable that has a ferrite core attached to it.

* To prevent malfunction and/or damages to speakers or other devices, always turn down the volume, and turn off the power on all devices 

before making any connections.

 

Set the mode of the S-4000M to [MERGE] and connect the S-0808 units to REAC ports 1 through 4. The S-4000M configures all 
REAC slave devices connected to REAC ports 1 through 4, so a REAC master device such as the V-Mixer sees the system as a single 
REAC slave device.

 

On the S-0808 units connected to REAC ports 1 through 4, set the REAC mode to “Slave.” For information about mode settings and operation in 

the respective modes, refer to the owner’s manual for the S-0808.

 

When connecting three or fewer devices, make the connections in sequence, starting from the lowest numbered REAC ports.

 

When communication is established between the S-4000M and the REAC master device connected to REAC port A, communication with the S-

0808 units connected to REAC ports 1 through 4 starts. When the S-0808 units connected to the S-4000M are detected and REAC communication 

is established, the [LINK] indicators 1 through 4 of REAC STATUS flash. If these do not flash, try detaching and reconnecting the cables and 

switching the power on and off.

 

When connections to REAC ports 1 through 4 are made, the input and output channel numbers of the respective S-0808 units 
detected by the REAC master device are as shown below. 

 

fig.S0808x4.eps

 

When S-0808 units are connected, the S-4000M also functions as their power-supply unit. This eliminates the need to connect external batteries 

to the S-0808 units. When power supply to the S-0808 units starts, the [POWER] indicator of REAC STATUS lights up.

 

If the mapping of the input and output channels is different from the arrangement shown above, use the [AUTO MAP SLAVE UNITS] button to 

redo the settings for the system. For information about how to make the settings, refer to “Resetting the System” (p. 20).

 

Before Making REAC Connections

Connecting S-0808 Units to REAC Ports 1 - 4

OUTPUT
INPUT

CH1 - 8

CH9 - 16

CH1 - 8

CH17 - 24

CH1 - 8

CH25 - 32

1

2

3

4

CH1 - 8
CH1 - 8

S-4000M_e.book 15 ページ 2014年11月26日 水曜日 午後4時4分

Summary of Contents for S-4000M

Page 1: ...ation of the unit Additionally in order to feel assured that you have gained a good grasp of every feature provided by your new unit owner s manual should be read in its entirety The manual should be...

Page 2: ...2 801 West Orchard Drive Suite 3 S 4000M_e book 2...

Page 3: ...terial coins pins or liquids of any kind water soft drinks etc to penetrate the unit 012a Immediately turn the power off remove the power cord from the outlet and request servicing by your retailer th...

Page 4: ...plug on the power supply cord when plugging into or unplugging from an outlet or this unit 103a At regular intervals you should unplug the power plug and clean it by using a dry cloth to wipe all dus...

Page 5: ...ect it to temperature extremes Excessive heat can deform or discolor the unit 355b When moved from one location to another where the temperature and or humidity is very different water droplets conden...

Page 6: ...Power On and Off 14 Turning the Power On 14 Turning the Power Off 14 Connecting Peripheral Devices 15 Before Making REAC Connections 15 Connecting S 0808 Units to REAC Ports 1 4 15 Connecting an V Mi...

Page 7: ...signals REAC devices are connected using Cat 5e Enhanced Category 5 Ethernet cable The S 4000M is designed to be a merge unit for REAC devices You can use it to manage connected REAC slave devices ma...

Page 8: ...splayed as follows POWER These light up when supplying power to powered devices of REAC EMBEDDED POWER LINK These flash when communication with connected REAC devices is established and light up stead...

Page 9: ...o not use cables with cut or torn on coverings Do not step on cables or subject them to undue stress Do not wind cables too tightly or bend them double To maintain transmission quality use of the foll...

Page 10: ...rom REAC slave devices connected to REAC ports 1 through 4 and outputs them to a REAC master device connected to REAC port A All the REAC slave devices are recognized by the REAC master as a single RE...

Page 11: ...s When the S 4000M is set to this mode the REAC port A is inactive When the S 4000M is set to this mode the REMOTE connector is inactive To control preamps connect one of followings to REMOTE connecto...

Page 12: ...ned about this connect the ground terminal see figure with an external ground When the unit is grounded a slight hum may occur depending on the particulars of your installation If you are unsure of th...

Page 13: ...nked 1 Detach the cord hook Remove the two retainer screws and detach the cord hook fig lift cramp eps 2 Connect the power cord to the AC INPUT connector fig connect AC eps 3 Secure the power cord in...

Page 14: ...00M 3 Turn on the power to the peripheral devices Turn on the power to the REAC devices connected to the S 4000M Devices powered by REAC EMBEDDED POWER may have no power switch On these devices the po...

Page 15: ...in sequence starting from the lowest numbered REAC ports When communication is established between the S 4000M and the REAC master device connected to REAC port A communication with the S 0808 units c...

Page 16: ...seen by the V Mixer as a single digital snake device In this case the S 0808 units are powered by the S 4000M so no external batteries are required In the figure shown below A and B and 1 through 4 r...

Page 17: ...mixer you can connect the S 4000M and the V Mixer via the S 4000D Connect the M 48 units to the S 4000D fig M48 connection eps When the connection shown here is made the S 0808 units are powered by th...

Page 18: ...ctive models When the S 4000M detects the connected S 4000H or S 4000S and REAC communication starts the A of LINK indicator in REAC STATUS flashes If this does not flash try detaching and reconnectin...

Page 19: ...be reset to match the newly connected device p 20 In the figures shown below 1 through 4 refer to the REAC port numbers fig variation eps Connecting Other Digital Snake Devices OUTPUT INPUT CH1 8 CH1...

Page 20: ...s are communicating correctly with the S 4000M Make sure that REAC STATUS LINK indicators 1 through 4 are all flashing 3 Reset the system Hold down the AUTO MAP SLAVE UNITS button for several seconds...

Page 21: ...l snake devices Installing dedicated remote control software on a computer and connecting it to the REMOTE connector lets you perform remote control from the computer As with the S 4000R you can use t...

Page 22: ...DED POWER Dimensions Weight Operation Temperature Accessories REAC EMBEDDED POWER Red x 4 REAC LINK Green x 5 POWER Blue x 1 AUTO MAP SLAVE UNITS Red x 1 AC 115V 117V 220V 230V 240V 50 60Hz Power Cons...

Page 23: ...23 Appendices Screw holes Bottom Chassis Dimensions UNIT mm Front Rear UNIT mm Fastening Screws Rubber Foot S 4000M_e book 23...

Page 24: ...24 Memo Memo S 4000M_e book 24...

Page 25: ...25 Memo Memo S 4000M_e book 25...

Page 26: ...For China S 4000M_e book 26...

Page 27: ...S 4000M_e book 27...

Page 28: ...5 1 0 0 0 1 2 6 2 5 0 4 S 4000M_e book 28...

Reviews: