Roland S-4000M Owner'S Manual Download Page 14

 

14

 

Turning the Power On and Off

 

Once you have made the correct connections, be sure to turn on the power in the sequence shown below. If the power is turned 
on in the wrong sequence, there can be danger of malfunction, or even blown speakers.

 

* Once the connections have been completed (p. 12), turn on power to your various devices in the order specified. By turning on devices in the 

wrong order, you risk causing malfunction and/or damage to speakers and other devices.

 

1.

 

Connect the peripheral devices.

 

Connect the REAC devices. Before making the connections, switch off the power to all REAC devices, including the S-4000M.

 

2.

 

Turn on the power to the S-4000M.

 

Set the [POWER] switch on the unit’s front panel to ON to switch on the power to the S-4000M.

 

3.

 

Turn on the power to the peripheral devices.

 

Turn on the power to the REAC devices connected to the S-4000M.

 

* Devices powered by REAC EMBEDDED POWER may have no power switch. On these devices, the power comes on automatically when the 

power to the S-4000M is switched on.

 

1.

 

Turn off the power to the peripheral devices.

 

Turn off the power to the REAC devices connected to the S-4000M.

 

2.

 

Turn off the power to the S-4000M.

 

Set the [POWER] switch on the unit’s front panel to OFF to switch off the power to the S-4000M.

 

* If any powered devices of REAC EMBEDDED POWER are being powered over REAC cables, switching off the power to the S-4000M automatically 

turns off the power to these devices as well.

 

* If you need to turn off the power completely, first turn off the POWER switch, then unplug the power cord from the power 

outlet. 

 

* After powering down all devices, detach the REAC cable.

 

Turning the Power On

Turning the Power Off

S-4000M_e.book 14 ページ 2014年11月26日 水曜日 午後4時4分

Summary of Contents for S-4000M

Page 1: ...ation of the unit Additionally in order to feel assured that you have gained a good grasp of every feature provided by your new unit owner s manual should be read in its entirety The manual should be...

Page 2: ...2 801 West Orchard Drive Suite 3 S 4000M_e book 2...

Page 3: ...terial coins pins or liquids of any kind water soft drinks etc to penetrate the unit 012a Immediately turn the power off remove the power cord from the outlet and request servicing by your retailer th...

Page 4: ...plug on the power supply cord when plugging into or unplugging from an outlet or this unit 103a At regular intervals you should unplug the power plug and clean it by using a dry cloth to wipe all dus...

Page 5: ...ect it to temperature extremes Excessive heat can deform or discolor the unit 355b When moved from one location to another where the temperature and or humidity is very different water droplets conden...

Page 6: ...Power On and Off 14 Turning the Power On 14 Turning the Power Off 14 Connecting Peripheral Devices 15 Before Making REAC Connections 15 Connecting S 0808 Units to REAC Ports 1 4 15 Connecting an V Mi...

Page 7: ...signals REAC devices are connected using Cat 5e Enhanced Category 5 Ethernet cable The S 4000M is designed to be a merge unit for REAC devices You can use it to manage connected REAC slave devices ma...

Page 8: ...splayed as follows POWER These light up when supplying power to powered devices of REAC EMBEDDED POWER LINK These flash when communication with connected REAC devices is established and light up stead...

Page 9: ...o not use cables with cut or torn on coverings Do not step on cables or subject them to undue stress Do not wind cables too tightly or bend them double To maintain transmission quality use of the foll...

Page 10: ...rom REAC slave devices connected to REAC ports 1 through 4 and outputs them to a REAC master device connected to REAC port A All the REAC slave devices are recognized by the REAC master as a single RE...

Page 11: ...s When the S 4000M is set to this mode the REAC port A is inactive When the S 4000M is set to this mode the REMOTE connector is inactive To control preamps connect one of followings to REMOTE connecto...

Page 12: ...ned about this connect the ground terminal see figure with an external ground When the unit is grounded a slight hum may occur depending on the particulars of your installation If you are unsure of th...

Page 13: ...nked 1 Detach the cord hook Remove the two retainer screws and detach the cord hook fig lift cramp eps 2 Connect the power cord to the AC INPUT connector fig connect AC eps 3 Secure the power cord in...

Page 14: ...00M 3 Turn on the power to the peripheral devices Turn on the power to the REAC devices connected to the S 4000M Devices powered by REAC EMBEDDED POWER may have no power switch On these devices the po...

Page 15: ...in sequence starting from the lowest numbered REAC ports When communication is established between the S 4000M and the REAC master device connected to REAC port A communication with the S 0808 units c...

Page 16: ...seen by the V Mixer as a single digital snake device In this case the S 0808 units are powered by the S 4000M so no external batteries are required In the figure shown below A and B and 1 through 4 r...

Page 17: ...mixer you can connect the S 4000M and the V Mixer via the S 4000D Connect the M 48 units to the S 4000D fig M48 connection eps When the connection shown here is made the S 0808 units are powered by th...

Page 18: ...ctive models When the S 4000M detects the connected S 4000H or S 4000S and REAC communication starts the A of LINK indicator in REAC STATUS flashes If this does not flash try detaching and reconnectin...

Page 19: ...be reset to match the newly connected device p 20 In the figures shown below 1 through 4 refer to the REAC port numbers fig variation eps Connecting Other Digital Snake Devices OUTPUT INPUT CH1 8 CH1...

Page 20: ...s are communicating correctly with the S 4000M Make sure that REAC STATUS LINK indicators 1 through 4 are all flashing 3 Reset the system Hold down the AUTO MAP SLAVE UNITS button for several seconds...

Page 21: ...l snake devices Installing dedicated remote control software on a computer and connecting it to the REMOTE connector lets you perform remote control from the computer As with the S 4000R you can use t...

Page 22: ...DED POWER Dimensions Weight Operation Temperature Accessories REAC EMBEDDED POWER Red x 4 REAC LINK Green x 5 POWER Blue x 1 AUTO MAP SLAVE UNITS Red x 1 AC 115V 117V 220V 230V 240V 50 60Hz Power Cons...

Page 23: ...23 Appendices Screw holes Bottom Chassis Dimensions UNIT mm Front Rear UNIT mm Fastening Screws Rubber Foot S 4000M_e book 23...

Page 24: ...24 Memo Memo S 4000M_e book 24...

Page 25: ...25 Memo Memo S 4000M_e book 25...

Page 26: ...For China S 4000M_e book 26...

Page 27: ...S 4000M_e book 27...

Page 28: ...5 1 0 0 0 1 2 6 2 5 0 4 S 4000M_e book 28...

Reviews: