Resetting the System

 

When the mode of the S-4000M is set to [MERGE], the mapping of the input and output channels detected by the REAC master 
device varies according to the type of devices connected to REAC ports 1 through 4. When a device connected to one of the REAC 
ports 1 through 4 is replaced by a different device, the system must be reset to match the newly connected device.

 

* This operation is not necessary when a digital snake device has been replaced by a device of the same type. Carry out this procedure only 

when a device has been replaced by another of a different type.

 

1.

 

Connect the digital snake devices.

 

Connect the digital snake devices to REAC port A or REAC ports 1 through 4 on the S-4000M.

 

2.

 

Check the communication with the S-4000M.

 

Check to make sure that all new connected digital snake devices are communicating correctly with the S-4000M. Make sure that 
REAC STATUS [LINK] indicators 1 through 4 are all flashing.

 

3.

 

Reset the system.

 

Hold down the [AUTO MAP SLAVE UNITS] button for several seconds. A system reset is executed, and the input and output 
channels are automatically assigned to match the newly connected digital snake devices.

 

* The button is slightly recessed from the surface of the panel. Use a screwdriver or other narrow-tipped implement to press the button.

 

fig.auto-map-button.eps

 

The [AUTO MAP SLAVE UNITS] indicator flashes while the system reset is in progress. All output is muted at this time, but in rare instances some 

noise may be heard. To be safe, before executing the system reset, turn down the output on all connected amps and speakers.

 

You can restore the unit to its factory-default state by performing a system reset while nothing is connected to any of the REAC ports. The factory-

default settings are the state described in “Connecting S-0808 Units to REAC Ports 1 - 4” (p. 15).

S-4000M_e.book 20 ページ 2014年11月26日 水曜日 午後4時4分

Summary of Contents for S-4000M

Page 1: ...ation of the unit Additionally in order to feel assured that you have gained a good grasp of every feature provided by your new unit owner s manual should be read in its entirety The manual should be...

Page 2: ...2 801 West Orchard Drive Suite 3 S 4000M_e book 2...

Page 3: ...terial coins pins or liquids of any kind water soft drinks etc to penetrate the unit 012a Immediately turn the power off remove the power cord from the outlet and request servicing by your retailer th...

Page 4: ...plug on the power supply cord when plugging into or unplugging from an outlet or this unit 103a At regular intervals you should unplug the power plug and clean it by using a dry cloth to wipe all dus...

Page 5: ...ect it to temperature extremes Excessive heat can deform or discolor the unit 355b When moved from one location to another where the temperature and or humidity is very different water droplets conden...

Page 6: ...Power On and Off 14 Turning the Power On 14 Turning the Power Off 14 Connecting Peripheral Devices 15 Before Making REAC Connections 15 Connecting S 0808 Units to REAC Ports 1 4 15 Connecting an V Mi...

Page 7: ...signals REAC devices are connected using Cat 5e Enhanced Category 5 Ethernet cable The S 4000M is designed to be a merge unit for REAC devices You can use it to manage connected REAC slave devices ma...

Page 8: ...splayed as follows POWER These light up when supplying power to powered devices of REAC EMBEDDED POWER LINK These flash when communication with connected REAC devices is established and light up stead...

Page 9: ...o not use cables with cut or torn on coverings Do not step on cables or subject them to undue stress Do not wind cables too tightly or bend them double To maintain transmission quality use of the foll...

Page 10: ...rom REAC slave devices connected to REAC ports 1 through 4 and outputs them to a REAC master device connected to REAC port A All the REAC slave devices are recognized by the REAC master as a single RE...

Page 11: ...s When the S 4000M is set to this mode the REAC port A is inactive When the S 4000M is set to this mode the REMOTE connector is inactive To control preamps connect one of followings to REMOTE connecto...

Page 12: ...ned about this connect the ground terminal see figure with an external ground When the unit is grounded a slight hum may occur depending on the particulars of your installation If you are unsure of th...

Page 13: ...nked 1 Detach the cord hook Remove the two retainer screws and detach the cord hook fig lift cramp eps 2 Connect the power cord to the AC INPUT connector fig connect AC eps 3 Secure the power cord in...

Page 14: ...00M 3 Turn on the power to the peripheral devices Turn on the power to the REAC devices connected to the S 4000M Devices powered by REAC EMBEDDED POWER may have no power switch On these devices the po...

Page 15: ...in sequence starting from the lowest numbered REAC ports When communication is established between the S 4000M and the REAC master device connected to REAC port A communication with the S 0808 units c...

Page 16: ...seen by the V Mixer as a single digital snake device In this case the S 0808 units are powered by the S 4000M so no external batteries are required In the figure shown below A and B and 1 through 4 r...

Page 17: ...mixer you can connect the S 4000M and the V Mixer via the S 4000D Connect the M 48 units to the S 4000D fig M48 connection eps When the connection shown here is made the S 0808 units are powered by th...

Page 18: ...ctive models When the S 4000M detects the connected S 4000H or S 4000S and REAC communication starts the A of LINK indicator in REAC STATUS flashes If this does not flash try detaching and reconnectin...

Page 19: ...be reset to match the newly connected device p 20 In the figures shown below 1 through 4 refer to the REAC port numbers fig variation eps Connecting Other Digital Snake Devices OUTPUT INPUT CH1 8 CH1...

Page 20: ...s are communicating correctly with the S 4000M Make sure that REAC STATUS LINK indicators 1 through 4 are all flashing 3 Reset the system Hold down the AUTO MAP SLAVE UNITS button for several seconds...

Page 21: ...l snake devices Installing dedicated remote control software on a computer and connecting it to the REMOTE connector lets you perform remote control from the computer As with the S 4000R you can use t...

Page 22: ...DED POWER Dimensions Weight Operation Temperature Accessories REAC EMBEDDED POWER Red x 4 REAC LINK Green x 5 POWER Blue x 1 AUTO MAP SLAVE UNITS Red x 1 AC 115V 117V 220V 230V 240V 50 60Hz Power Cons...

Page 23: ...23 Appendices Screw holes Bottom Chassis Dimensions UNIT mm Front Rear UNIT mm Fastening Screws Rubber Foot S 4000M_e book 23...

Page 24: ...24 Memo Memo S 4000M_e book 24...

Page 25: ...25 Memo Memo S 4000M_e book 25...

Page 26: ...For China S 4000M_e book 26...

Page 27: ...S 4000M_e book 27...

Page 28: ...5 1 0 0 0 1 2 6 2 5 0 4 S 4000M_e book 28...

Reviews: