< PQ
Phrase Setting Contents Request
Function 1: Phrase setting contents request
Syntax:
stxPQ:a;
a: Phrase number
Note:
The phrase settings for the specified phrase number will be output.
The value of the Phrase Output Counter (described below) will not change.
(---> refer to the SU command)
Function 2: If the phrase number is not specified as a parameter, the AR-3000R will output the
phrase settings for automatically incremented phrase number by the Phrase Output
Counter.
Syntax:
stxPQ:;
Note:
The incremented value will skip phrase numbers which are not recorded yet, and will be up
to the next recorded phrase number. If the PQ command is used to request output even
after the setting information of the last phrase has been output, the AR-3000R will output
“stxER:101;”.
In the case of a Pattern Phrase, you must use the separately described 3Q command to
request output of the settings. (---> refer to 3Q command)
* About the Phrase Output Counter
The AR-3000R contains the Phrase Output Counter. The maximum value of this counter is
the maximum phrase number of each card. The counter is reset (i.e., to the lowest phrase
number) by the AQ command. So you can request each phrase settings of all phrases in the
card by sequentially using the PQ command’s function 2 after resetting the counter.
Phrase Setting Contents Request
Function 1: Phrase setting contents request
Syntax:
stxQQ:a;
a: Phrase number
Note:
The phrase settings for the specified phrase number will be output.
The value of the Phrase Output Counter (described below) will not change.
(* refer to the RU command)
Function 2: If the phrase number is not specified as a parameter, the AR-3000R will output the
phrase settings for automatically incremented phrase number by the Phrase Output
Counter.
Syntax:
stxQQ:;
Note:
The incremented value will skip phrase numbers which are not recorded yet, and will be up
to the next recorded phrase number. If the PQ command is used to request output even
after the setting information of the last phrase has been output, the AR-3000R will output
“stxER:101;”
In the case of a Pattern Phrase, you must use the separately described 3Q command to
request output of the settings. (* refer to 3Q command)
* About the Phrase Output Counter
The AR-3000R contains the Phrase Output Counter. The maximum value of this counter is
the maximum phrase number of each card. The counter is reset (i.e., to the lowest phrase
number) by the AQ command. So you can request each phrase settings of all phrases in the
card by sequentially using the QQ command’s function 2 after resetting the counter.
AR-3000
R Ver.2.01 R
S-232C Reference - 35