2-2 Step 1: Install the Unit
28
Chapter 2 Installation
For a T-slot Table
The installation method differs depending on the type of table attached. If you're using a modeling machine equipped with
a T-slot table, then use this method to install.
Procedure
Prepare the modeling machine.
Remove any tools.
Use manual feed to move the table
toward the front.
Shut down the modeling machine
and disconnect the power cable.
WARNING: Be sure to disconnect
the power cable. Failure to do so
may result in danger of injury.
Gently turn the workpiece chuck by hand until the installation hole can be seen.
Slide the T-slot nut into the groove.
Attach the drive unit.
Slide the T-slot nut into the groove.
Attach the tailstock.
Stopper
Butt this flush against
the edge of the table.
Cap screw
(M8 x 20
mm)
T-slot nut
Tab
Butt this flush at the front.
Cap screw
(M8 x 20 mm)
T-slot nut