50
Table 1.0 Command ID
Data Byte
Data Type
Byte details
7 ------- 0
Data Details
$1e (30) = DCO2 PWM Amount
0xxxxxxx
(0-127)
$1f (31) = DCO2 DYN Amount
0xxxxxxx
(0-127)
$20 (32) = DCO Cross Mod
000000xx
xx =
00=off
01=sync1
10=sync2
11=metal
$21 (33) = DCO2 Control
0wwxyyzz
zz =
DCO2Env(00=Env1,01=Env2,10=Env3)
yy =
DCO2LFO(00=LFO1,01=LFO2,10=LFO3)
x =
DCO2Env Pol(0=Norm,1=Inverted)
ww =
DCO2PWM Src(00=Env1,01=Env3,10=LFO2,11=LFO3)
$22 (34) = Detune Amount
0xxxxxxx
(0-127)
$23 (35) = DCO Mix
0xxxxxxx
(0-127)
$24 (36) = DCO Mix Env Level
0xxxxxxx
(0-127)
$25 (37) = DCO Mix DYN
0xxxxxxx
(0-127)
$26 (38) = DCO Mix Control
000000zz
zz =
MixEnv(00=Env1,01=Env2,10=Env3)
$27 (39) = HPF Level
0xxxxxxx
(0-127)
$28 (40) = VCF Cutoff Hi
000xxxxx
$29 (41) = VCF Cutoff Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
x = Range $0-$fff (0-4095)
$2a (42) = VCF Resonance Hi
000xxxxx
$2b (43) = VCF Resonance Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
x = Range $0-$fff (0-4095)
$2c (44) = VCF LFO Mod Amount
0xxxxxxx
(0-127)
$2d (45) = VCF Env Mod Amount
0xxxxxxx
(0-127)
$2e (46) = VCF Key Mod Amount
0xxxxxxx
(0-127)
$2f (47) = VCF Key DYN Amount
0xxxxxxx
(0-127)
$30 (48) = VCF Control
000xyyzz
zz =
VCFEnv(00=Env1,01=Env2,10=Env3)
yy =
VCFLFO(00=LFO1,01=LFO2,10=LFO3)
x =
VCFEnv Pol(0=Norm,1=Inverted)
$31 (49) = VCA Level
0xxxxxxx
(0-127)
$32 (50) = VCA LFO Mod Amount
0xxxxxxx
(0-127)
www.kiwitechnics.com
3P Matrix Upgrade User Manual v1.2
Summary of Contents for KIWI-3P
Page 5: ...5 Front Panel Description www kiwitechnics com 3P Matrix Upgrade User Manual v1 2 ...
Page 6: ...6 Basic Connections www kiwitechnics com 3P Matrix Upgrade User Manual v1 2 ...
Page 7: ...Menu Flow Chart ...
Page 8: ...8 Edit Map www kiwitechnics com 3P Matrix Upgrade User Manual v1 2 ...