background image

LOAD

Menu Description

 

LOAD

 

Stored in Memory

Yes

Factory Default

USER1

Selection Choices

USER1, USER2, USER3, or USER4

 

Description 

Calls up the setting values stored using SAVE. 
 

Summary of Contents for GX-24

Page 1: ...GX 24 Control Panel Flow Chart Visual Representation of the GX 24 Control Panel This guide is a visual representation of the GX 24 menu structure with descriptions Clicking on the menu in the flow cha...

Page 2: ...the setting is stored even when the power is turned off Factory Default Indicates the factory default setting Setting Range or Selection Choices Indicates the range in which the settings can be specif...

Page 3: ...Menu Flow Chart Menu Flow Chart Display Menu...

Page 4: ...Menu Flow Chart Back Next...

Page 5: ...Menu Flow Chart Menu Flow Chart Cutting Force Setup Menu Origin Setup Menu Pause Menu Language Selection Menu...

Page 6: ...Description ROLL Performs cutting using roll material PIECE Performs cutting using standard size material or piece material EDGE When using roll material cutting is performed from the front left edge...

Page 7: ...UNSETUP Menu Description UNSETUP Stored in Memory No Description Releases the setup condition when executed...

Page 8: ...or long flat material that exceeds 1 6 m in length This ensures that the material will not come loose during cutting by feeding out the length of material to be cut before actually performing cutting...

Page 9: ...on SPEED Stored in Memory Yes Factory Default 20 cm s Setting Range 1 to 50 cm s 1 cm s steps Description Sets the speed used when cutting material Set this to a suitable value for the loaded material...

Page 10: ...ored in Memory Yes Factory Default 50 gf Setting Range 30 to 250 gf 10 gf steps Description Sets the blade force used when cutting material Perform a cutting test and set the conditions to match the l...

Page 11: ...ting Range 0 000 to 1 000 mm 0 025 mm steps Description Sets the amount of offset for the tip of the blade Set a value that matches the conditions for the blade installed When using the included blade...

Page 12: ...e the origin is set at the lower left of the material When set to 90deg the origin is set at the lower right of the material and the data is rotated counterclockwise by 90 degrees Note that when 90deg...

Page 13: ...the next cutting position with the blade lifted off the material during cutting operation If set to AUTO the blade moves at the speed specified by SPEED If UPSPEED is increased the cutting time is sh...

Page 14: ...lt USER1 Selection Choices USER1 USER2 USER3 or USER4 Description Stores the setting values of menus that are now being used The menus that you can register are as follows FORCE SPEED OFFSET UPSPEED a...

Page 15: ...LOAD Menu Description LOAD Stored in Memory Yes Factory Default USER1 Selection Choices USER1 USER2 USER3 or USER4 Description Calls up the setting values stored using SAVE...

Page 16: ...ed in Memory Yes Factory Default ON Selection Choices ON or OFF Description ON Cuts curves such as arcs smoothly However the corners may be rounded when a small character or a complex shape is cut OFF...

Page 17: ...Memory Yes Factory Default ENGLISH Selection Choices ENGLISH PORTOG ITAL ESPAN FRANC or DEUT Description Selects the language for messages on the display ENGLISH English Japanese PORTOG Portuguese IT...

Page 18: ...ry Yes Factory Default mm Selection Choices mm or inch Description Selects the unit of measurement for numerical values shown on the display However values are shown in metrics for the following menus...

Page 19: ...FACTORYDEFAULT Menu Description FACTORYDEFAULT Description Resets the display menu values to the same settings as their factory defaults However the setting for LANG is not reset...

Page 20: ...ects the port automatically The communication parameters for serial connection are set according to the settings made on the GX 24 If the interface is not recognized correctly when set to AUTO use the...

Page 21: ...on BAUD Stored in Memory Yes Factory Default 9600 Selection Choices 4800 or 9600 Description Sets the communication speed for a serial connection It is effective only when connected to the computer us...

Page 22: ...ription DATA Stored in Memory Yes Factory Default 8 Selection Choices 8 or 7 Description Sets the number of data bits for a serial connection It is effective only when connected to the computer using...

Page 23: ...ription STOP Stored in Memory Yes Factory Default 1 Selection Choices 1 or 2 Description Sets the number of stop bits for a serial connection It is effective only when connected to the computer using...

Page 24: ...ARITY Stored in Memory Yes Factory Default NONE Selection Choices NONE EVEN or ODD Description Sets the type of parity checking for a serial connection It is effective only when connected to the compu...

Page 25: ...ND Stored in Memory Yes Factory Default H WIRE Selection Choices H WIRE or XONOFF Description Sets the handshaking flow control for a serial connection It is effective only when connected to the compu...

Page 26: ...ription Executes a self test to check the status of the GX 24 Use this to check the GX 24 when it appears to be not operating correctly If the self test is executed and the test pattern in the figure...

Page 27: ...T Stored in Memory No Selection Choices START or CLEAR Description START Performs cutting using the data in the replot buffer when the ENTER key is pressed CLEAR Deletes the data in the replot buffer...

Page 28: ...LENGTH Menu Description MANUAL START Description Starts the reading of crop marks This can be executed only when CROPMARK is set to MANUAL...

Page 29: ...ing Range 50 to 500 mm 1 mm steps Description Sets the distance between the centers of the top and bottom crop marks Specify the same value as the distance between the center of the two crop marks spe...

Page 30: ...ng Range 50 to 610 mm 1 mm steps Description Sets the distance between the centers of the right and left crop marks Specify the same value as the distance between the center of the two crop marks spec...

Page 31: ...ng Range 0 0 to 50 0 mm 0 1 mm steps Description Specifies the distance in Y direction between the center of a crop mark and the origin point Normally set the value to the radius of the crop marks spe...

Page 32: ...ng Range 0 0 to 50 0 mm 0 1 mm steps Description Specifies the distance in X direction between the center of a crop mark and the origin point Normally set the value to the radius of the crop marks spe...

Page 33: ...K Stored in Memory Yes Factory Default AUTO Selection Choices AUTO or MANUAL Description Sets the method for reading crop marks If MANUAL is selected the crop marks must be specified by entering the s...

Reviews: