Installation Manual
17
Programming Your ORBIT-14
Programming Methods
Local Requirements
LED or LCD keypads
The keypad must be wired to the
ORBIT-14 panel.
Power must be applied to the ORBIT-14.
ORBIT Programmer
Easy programming of the control panel
parameters with menu driven LCD
display.
The programmer can store up to 10
ORBIT-14 programming sets and copy
them directly to the panel.
The programmer will be connected to
and receive its power from the panel.
P/N: RP214PR00XXA*
*: XX represents the programmer
language interface.
Local ORBIT UD*
Local Up/Load Windows version from a
personal computer.
The software must be installed and an
ORBIT UD Adaptor cable is connected
between the panel and the computer.
P/N for the local adapters:
RP214LU0000A: Local Bus Adapter.
RP214USB000A: USB/RS232 Bus
Adapter.
Remote ORBIT UD*
Remote U/D Windows version from a
personal computer.
The software and applicable modem with
configured access to a telephone line
must be installed.
* Compatible with Windows 95/98/2000 XP. (P/N RP128UD0000A)
Viewing the Contents of a Location
It is often necessary to check the data stored in a memory
location to ensure that it is correct. If improper data is found, it
must be corrected in order to obtain the desired system response.
The data in a location can either be a number (from 0-9) or a
letter (from A-F), taking advantage of the hexadecimal numbering
system. For our purposes, the characters A through F will be
referred to as hexadecimal digits.
Whenever the Installer Programming mode is active, the first four
Zone LEDs on the keypad (1-4) are used to reveal each digit in a
selected location. By adding up the values assigned to the lit
LEDs, the contents of any
location can be determined. See the
table below.