background image

Technical Note

 

18/20

 

BH1730FVC 

www.rohm.com 

2012.02 - Rev.A

© 2012 ROHM Co., Ltd. All rights reserved. 

The method of distinguishing 1pin. 

 

There is some method of distinguishing 1pin. 

  Distinguishing by 1Pin marking 

  Distinguishing by die pattern 

  Distinguishing by taper part of 1-3pin side 

 

(by die pattern) is the easiest method to distinguish by naked eye. 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Production code 

 

 

A

 

H

 

 

Summary of Contents for BH1730FVC

Page 1: ...interface 8 Light source dependency is little by calculating with Type0 and Type1 ex Incandescent Lamp Fluorescent Lamp Halogen Lamp White LED Sun Light 9 Interrupt function is available 10 Adjustable...

Page 2: ...1h DAh 1 Gain X2 resolution in Type0 rG2 0 42 lx count TIMING register 01h DAh 1 Gain X64 resolution in Type0 rG64 0 014 lx count TIMING register 01h DAh 1 Gain X128 resolution in Type0 rG128 0 007 lx...

Page 3: ...Ah Fig 9 VCC ICC During measurement Fig 1 Spectral Response of Type0 visible light peak 0 0 2 0 4 0 6 0 8 1 1 2 2 2 5 3 3 5 4 VCC V Ratio Fig 11 Measurement Result VCC Dependency DVI 1 8V 0 0 2 0 4 0...

Page 4: ...erter for obtainment digital 16bit data ADC Logic I 2 C Interface INT Interface Ambient light calculation logic and I 2 C Bus Interface and Interrupt function Interface OSC Internal oscillator typ 360...

Page 5: ...mmand register is used 3 Case of write to data register after write to Command Register ST Slave Address 0101001 W 0 ACK Data to Command Register 1XXXXXXX ACK Data specified at register address field...

Page 6: ...g DVI L Initial reset is not necessary because power on reset function is included in this product 2 Software reset command All registers are reset and BH1730FVC becomes power down by Software reset c...

Page 7: ...threshold setting 07h RW GAIN Gain control 12h R ID Part number and Revision ID 14h R DATA0LOW ADC Type0 low byte data register 15h R DATA0HIGH ADC Type0 high byte data register 16h R DATA1LOW ADC Ty...

Page 8: ...ges to power down automatically DATA_SEL 2 RW 0 ADC measurement Type0 and Type1 1 ADC measurement Type0 only ADC_EN 1 RW 0 ADC measurement is not started 1 ADC measurement is started POWER 0 RW 0 ADC...

Page 9: ...each measurement end 0010 Interrupt status is updated if two consecutive threshold judgments are the same When set 0011 or more interrupt status is updated if threshold judgments are the same over con...

Page 10: ...ription Part number 7 4 R 0111 Revision ID 3 0 R XXXX DATA0 14h 15h 7 6 5 4 3 2 1 0 ADC Type0 data default value 00h Register Address Bit Type Description DATA0 LSBs 14h 7 0 R Lower byte DATA0 MSBs 15...

Page 11: ...yp 100ms max 150ms and GAIN 00h X1 Gain at default Read measurement result ST Slave Address 0101001 W 0 ACK Write Command Register 1001_0100 ACK SP ST Slave Address 0101001 R 1 ACK Read DATA0 LSBs reg...

Page 12: ...utputs The calculation formula depends on the characteristic of optical window The example of the calculation is shown as follows Ex No optical window or optical window that has flat transmittance fro...

Page 13: ...old INT pin outputs L Interrupt threshold is defined at Interrupt threshold registers 03h 06h Interrupt function is able to control by Interrupt opecode Interrupt persistence is defined at Interrupt o...

Page 14: ...CC Power supplies There is some cautions about power on and down sequence seeing in below Power on time t1 More than 2ms is need to active BH1730FVC after VCC supplies more than 2 0V from VCC is less...

Page 15: ...026 Default Default 6 711 range of TIMING binary 1111_1111 1101_1010 0000_0001 range of TIMING decimal 255 218 1 Measurement time 2 7ms 102 6ms 688 5ms It is possible to detect 0 001 lx by using this...

Page 16: ...use INT Pin please connect to GND or open 3 GND GND terminal 4 SDA I 2 C bus Interface SDA terminal 5 DVI SDA SCL reference voltage terminal and asynchronous reset terminal for internal registers Init...

Page 17: ...rights reserved Package Outlines About an optical design on the device 0 8 mm 1 3 mm Sensitivity area 0 25mm x 0 3mm Please design the optical window so that light can cover at least this area Min 0...

Page 18: ...ghts reserved The method of distinguishing 1pin There is some method of distinguishing 1pin Distinguishing by 1Pin marking Distinguishing by die pattern Distinguishing by taper part of 1 3pin side by...

Page 19: ...r supply and then dismount it from the jig In addition for protection against static electricity establish a ground for the assembly process and pay thorough attention to the transportation and the st...

Page 20: ...tity needs to be multiple of the minimum quantity Tape and Reel information Embossed carrier tape Tape Quantity Direction of feed The direction is the 1pin of product is at the upper right when you ho...

Page 21: ...ical information The Products specified in this document are intended to be used with general use electronic equipment or devices such as audio visual equipment office automation equipment commu nicat...