39 / 191 - EN -
7.
Installation
7.1.
Power connection & residual current circuit breaker instructions
To operate the pugmill in workshops, laboratories and other environments, it is absolutely necessary to have a
separate power supply with its own protection provided by a qualified electrician. An RCD residual current circuit
breaker should be used for this (colloquially: RCCB or ELCB).
7.2.
Connecting the pugmill to the mains
7.2.1.
General description
Insert the power cable with the plug into the suitably prepared power connection at the operating location. The
machine must not be operated with an extension cable!
7.2.2.
Note on the direction of rotation (only the 400 V TS 20)
8.
Operation
8.1.
General safety information
DANGER
Danger of physical injury!
Risk of rotating parts causing physical injury!
Reaching into the mixing barrel during operation is strictly forbidden.
If the pugmill with a 400 V connection (CEE 16 A plug) does not turn in the direction
of the arrow indicated on the mixing barrel, 2 of the phases in the socket must be
swapped over by a qualified electrician. The CEE 16 A socket must have a
clockwise rotating field.
Note:
The work may only be carried out by a qualified electrician.
Summary of Contents for TS 20
Page 194: ...20220224 01 ...