![Rohde & Schwarz TSMX-PPS2 Getting Started Download Page 52](http://html1.mh-extra.com/html/rohde-and-schwarz/tsmx-pps2/tsmx-pps2_getting-started_1477706052.webp)
R&S
TSMX-PPS2
Using u-center Software
Getting Started 1515.7236.02 - 02
34
6.3.2 Resetting Sensor Calibration
Select “EKF” message in the “Configuration View”
u-center:
Select menu “View”
Configuration View
EFK
Tick at “Clear
Calibration Data”
Click on “Send” in the left lower corner
Figure 6-4: UBX Configuration Message “EKF”- Reset Sensor Settings
6.3.3 Time Pulse Settings
Select “TP” message in the “Configuration View”
u-center:
Select menu “View”
Configuration View
TP (Timepulse)
Configurable parameters:
Pulse Mode
:
defining edge for precision (rising or falling)
Pulse Period
: output frequency of time pulse
Pulse Length
: pulse length of the time pulse
Time Source
: reference for the time pulse (GPS time, UTC, etc.)
For default settings please refer to section
.
Figure 6-5: UBX Configuration Message “TP”- Time Pulse Settings
To keep settings after re-powering the device, it is necessary to safe the configuration
in the flash (see section
on page 36).