Function Description
R&S
®
TS-PIO2
22
User Manual 1506.7208.12 ─ 06
●
rspio2_Disconnect
●
rspio2_DisconnectAll
Function
rspio2_DisconnectAll
can be used to break all connections created with
rspio2_Connect
with a single function call.
rspio2_DisconnectAll
has no effect on the configuration of outputs, coupling
relays, or the ground relay.
5.1.3.4
Switching outputs
Function
rspio2_ConfigureOutputMux
configures the switching state of the out-
puts of a channel. The following settings are possible:
●
Output disconnected
●
Output connected with front side connector (CHx_OUT1)
●
Output connected with corresponding input (CHx_IN)
Please note that function
rspio2_DisconnectAll
does not affect this setting!
5.1.3.5
Coupling relay
The coupling relays connect the local analog bus (LAB) on the module with the analog
bus in the R&S CompactTSVP or R&S PowerTSVP. The function
rspio2_ConfigureCoupling
defines the status of the coupling relays.
Please note that function
rspio2_DisconnectAll
does not open these relays!
5.1.3.6
Ground relays
The R&S TS-PIO2 module has a ground relay that can be used to connect the poten-
tial-free module ground (AGND) with ground (GND).
Function description of the R&S TS-PIO2 module