Noise-Limited OTA Performance in Transmit Diversity Mode
R&S
®
AMS32-K31
12
User Manual 1175.6678.02 ─ 01
In the "Connection" tab of the driver configuration dialog, you can select the DL "Trans-
mission Scheme" and the allocated DL and UL resource blocks. Check "Setup Connec-
tion" to transfer your settings to the R&S CMW500.
To measure in line with the test case "noise-limited OTA performance in transmit diversity
mode", select "TX Diversity" as a transmission scheme and to configure a low-order,
robust modulation scheme, typically QPSK, with a low transport block size index.
For detailed information about the communication settings, refer to the R&S CMW500
documentation. Click "OK" to confirm your settings and return to the "OTA Auto Test
Template" dialog.
2.1.2.3
Measurement Settings
In the "Measurement Settings" dialog, you can select the measured quantity and test
procedure and specify the measurement statistics.
Access:
"Measurement Settings" button in the "OTA Auto Test Template" dialog; see
.
Configuration