RC Commands
R&S
®
OSP
295
User Manual 1178.7100.02 ─ 05
All path filenames have the extension "
.path
". Do not enter the extension when speci-
fying a filename. A filename query does not return the extension.
For example, when you save the path file "
gen-pa_1
", it is saved as
"
gen-pa_1.path
". A query returns this filename as "
gen-pa_1
", only.
Setting parameters:
<dummy>
This parameter is required but not evaluated. It can have any
integer numerical value (no decimal places).
<filename>
String parameter to specify the name of the file to be stored.
Usage:
Event
Manual operation:
See
ROUTe:MODule:CATalog?
Provides compatibility of remote control commands with legacy switch units
R&S
OSP120/130/150.
Returns a list of all hardware-detected modules installed in all legacy switch units in an
interconnection setup.
Example:
ROUT:MOD:CAT?
Return string:
"OSP-B101|F01M01","OSP-B123|F01M02",
"OSP-B123|F01M03"
The response contains the module type (e.g. R&S
OSP-B101)
and the internal module name (e.g.
F01M01
).
In the comma-separated string, each module's information is in
quotation marks.
If you enable the
, the module index is
returned as "A11" rather than "M01". Also, a hyphen is used
instead of the vertical line character. Hence, an example for a
segment in the return string is
"OSP-B101-F01A01"
.
If no installed module is detected, the following SCPI error is
generated (which you can query by
-200,"Execution error;ROUTe:MODule:CATalog?"
Usage:
Query only
READ:IO:IN4?
READ:IO:IN5?
READ:IO:IN16?
Provides compatibility of remote control commands with legacy switch units
R&S
OSP120/130/150.
Like
, these commands query the states of all 4, 5 or 16 input channels
of a selected I/O module.
Usage:
Query only
Legacy System Commands from R&S
OSP1x0