Network and remote operation
R&S
®
NRPM
91
Mannual 1425.8663.02 ─ 08
The syntax of the used USB resource string is:
USB::<vendor ID>::<product ID>::<serial number>[::INSTR]
Where:
●
<vendor ID> is the vendor ID for Rohde
&
Schwarz (0x0AAD).
●
<product ID> is the product ID for the Rohde
&
Schwarz sensor module.
●
<serial number> is the individual serial number at the rear of the sensor mod-
ule.
Table 9-2: R&S
NRPM3(N) USB product IDs
Sensor module
USB product ID
R&S
NRPM3
0x0195
R&S
NRPM3N
0x0196
Example:
USB::0x0AAD::0x0196::100001
0x0AAD is the vendor ID for the Rohde
&
Schwarz sensor module.
0x0196 is the product ID for the particular model (here R&S
NRPM3N sensor
module).
100001 is the serial number of the sensor module.
9.1.2
Ethernet interface
The Ethernet interface of the R&S
NRPM3N LAN sensor modules allows you to
integrate them in a local area network (LAN).
For remote control via a network, the computer and the sensor module must be
connected via the Ethernet interface to a common network with TCP/IP network
protocol. The TCP/IP network protocol and the associated network services are
preconfigured on the sensor module. Software for device control and the VISA
program library must be installed on the computer.
9.1.2.1
VISA resource string
The VISA resource string is required to establish a communication session
between the controller and the R&S
NRPM3N in a LAN. The resource string is a
Remote control interfaces and protocols